Disassembly / 拆卸; Precautions For Disassembly - Kenwood NXR-1700 Service Manual

Vhf repeater
Hide thumbs Also See for NXR-1700:
Table of Contents

Advertisement

3.1

Precautions for Disassembly

3.1.1 TX-RX UNIT disassembly procedure
(1) Remove the 12 screws on the top of the repeater and
remove the top plate. <1>
(2) Disconnect the FPC from the TX-RX UNIT connector. <2>
Screw x12
<1>
Top plate
FPC
<2>
(3) Pull out the knob and remove the 5 screws then remove the
PANEL ASSY from the chassis. <3> <4>
When the knob is pulled out, the spring inside the knob is
removed at the same time.
PANEL ASSY
Knob
<3>
Screw x5
<4>
Knob spring
1-50 (No.RA095<Rev.001>)
SECTION 3
DISASSEMBLY / 拆卸
Chassis
(4) Remove the solder connecting the two receptacles and TX-
RX UNIT. <5>
(5) Disconnect the fan motor wire from the TX-RX UNIT
CN3005. <6>
<5>
(6) Remove the 21 PCB screws and the 2 shielding case
screws. <7> <8>
(7) Remove the TX-RX UNIT from the chassis.
PCB
Screw x21
<7>
TX-RX UNIT
Note:
The power connector of the service TX-RX UNIT is not
fixed with screws. When replacing a defective TX-RX UNIT
with a service TX-RX UNIT, the power connector should be
fixed with the reuse screws of the TX-RX UNIT.
Screw x2
Power connector
Desoldering
<5>
Desoldering
<6>
CN3005
Shielding case
Screw x2
<8>
Service TX-RX UNIT

Advertisement

Table of Contents
loading

Table of Contents