Electrical Specifications

AC Voltage
• Main Board: 120 VAC to the J101
• Drain Pump: Should read approximately
13.2-ohms, 120 VAC
• Mode Shifter Motor: Should read
approximately 5.7k ohms, 120 VAC
• Water Valves: Should read approximately
1.3k ohms, 120 VAC
• Lid Lock Position Locked/Unlocked: Lid
Lock Coil approximately 60- to 100-ohms
between pins 2 and 3 when locked, and pins
1 and 3 when unlocked with the lid closed.
• Dosing Pump: Should read approximately
1.7k ohms, 120 VAC
• Bulk Tank Level Sensor: 5 VDC
DC Voltage
• User Interface (UI) Logic Board: 12 VDC /
7.5 VDC
• Hall Sensor: 9 VDC pin 3 to pin 2
• Accelerometer: 5 VDC
• Turbidity Sensor: 5 VDC
• Pressure Sensor: (See the Pressure
Sensor section of this service guide)

Specifications

Water Levels

– 8 –
Gallons
Inches
Comment
10.0
5.1
Min Fill
36.0
17.4
Max Fill