Direct Drive Motor - Haier GE PTW600BPR DG Series Technical Service Manual

Profile 28-in. top load washer
Table of Contents

Advertisement

Direct Drive Motor

The direct drive motor is a three-phase motor.
The three-phase inverter is incorporated into the
main board and provides to power the direct drive
motor. The direct drive motor consists of a rotor
and stator.
Direct Drive Motor Diagnosing
The output voltage from the inverter to the motor
is variable and should not be tested. The direct
drive motor resistance may be verified at the main
board, J1001, 5.8-ohms between pins 6 and 7, 7
and 8, 6 and 8.
Direct Drive Motor Removal
1. Unclip the main harness from the motor
connector by pushing down on the connector
clip. The clip is large enough that it can be
done with one hand. The motor side of the
harness is secured in place.
2. Remove rotor nut that secure the stator and
rotor and pull up the rotor.
Rotor
Rotor Nut
– 48 –
3. Unplug the speed sensor which is attached to
the stator assembly.
Speed Sensor
Connector
4. Remove three fasteners hex-head screw
which is securing stator to the platform and
pull up the stator assembly.
5. Slide down the speed sensor with harness to
release from stator motor.
Fasteners
Mode Shifter
Connector
Sensor

Advertisement

Table of Contents
loading