ADJUSTMENT
Measurement
Adjustment
Item
Condition
oqhestont
Unit | Terminal | Unit | Parts
Method
Specifications/Remarks
6. Power (APC)| 1) Connect the power meter
Power meter
EXT. ANT ; APC
| VR1
Power MAX,
5.5W or more.
adjustment
to EXT. ANT.
Freq'
T.SW : Set to @ position.
counter
CH : Channel with highest
DC ammeter
TX FREQ' (fTH).
PTT : ON
2) CH : Channe! with lowest
TX FREQ! (ft).
PTT : ON
Power meter
3) CH : Channel with TX center
aaa
VR2
Power MIN.
+0.3W
PTT: ON
over
.
6
1.0W ADJ.
£0.2W
4) CH : Channel with TX center
og
VR1
5.0W ADJ.
+0.2W
FREQ! (Fr).
Deviation meter
2 7A or less.
PTT: ON
see
5) CH : Check other channel
eS © ee
Check
4W or more.
PTT: ON
Freq' counter
2.7A or less.
(goeaeeéaa) (©)
AG
AFVTVM
o
©9
°
=)
(PS
]
ox a
BL°} | Sue
st
]
+1
1K
10nV 16V
7. DOT
1) CH : Set the channel selector | Power meter
TX-RX | VR4
Make the de-
waveform
to the channel with which
Deviation
modulation
correction
DOT is used.
meter
waveform neat.
Deviation meter filter
Oscilloscope
|
HPF : OFF
LPF : 3kHz
PTT : ON
8. QT
1} CH : Set the channel selector
TX-RX | VR5
+0.75kHz
+100Hz
to the channel with which
QT/CTCSS is used.
Deviation meter filter
HPF : OFF
LPF : 3kHz
De-emphasis
: 750us
PTT : ON
9. Maximum
| 1) AG : 1kHz/150mV at MIC in
MIC
TX-RX | VRB
| +4.4kHz
+100Hz
deviation
Deviation meter filter
(£4.9kHz ADJ.
adjustment
HPF : OFF
when using a
LPF : 15kHz
QT/DQT)
De-emphasis : OFF
Adjust orfe more
PTT : ON
than the other by
switching between
—P and +P.
10. MIC
1) AG : 1kHz/15mV at MIC in
TX-RX | VR1
+3kHz ADJ.
£100Hz
sensitivity
PTT: ON
(£3.75kHz ADJ.
adjustment
when using a
signaling)
11. DIME
1) CH : Channel with TX center
TX-RX
|VR2
| +2.8kHz ADJ.
+100Hz
(KDM-4/4A
FREQ' (fT).
installed)
Connect the DTMF board.
Keyboard :[1] push
PTT: ON
62