2.
Remove the side-mounted screw, set the two dry-cell batteries (type 9 V).
DC power supply can be use in place of the dry-cell batteries. (DC12 V to 24 V)
2-8-4. Operation of Pressure Indicator
•
Perform the setting (Focus mode, -40.0 kPa)
1.
Press the MODE button for 3 seconds or more.
2.
Press the MODE button at 1 time.
Press the ▽ button, and select the Foc mode.
3.
4.
Press the MODE button at 1 time.
Press the ▽ button, and change to "-40.0".
5.
6.
Press the MODE button at 6 times.
7.
Indicated value is changed to "FFF".
•
Initialize
Press the set button 5 times with holding down the MODE button.
2-8-5. The Switch of Air-leak Tester (Compressor Type)
Air Switch
Open
Close
Pressure Regulator Knob
Turn to the Right : Decrease in pressure
Turn to the Left : Increase in pressure
Sony CONFIDENTIAL
For Authorized Servicer
21
SYS SET