Technical Parameters & Block Diagram; Technical Parameters - GE GEP12-L-10 User Manual

12-60kw three phase
Hide thumbs Also See for GEP12-L-10:
Table of Contents

Advertisement

Type of fault
Relay-check Failure
DCI High
Inverter
1. Disconnect the DC connector.
EEPROM R/W Failure
2. Reconnect the DC connector.
Failure
SPI Failure
3. If the problem still exists, please call the local service office.
DC Bus High
GFCI Failure
1. Disconnect the DC switch, take off DC connector, measure the voltage
of PV string.
2. Plug in DC connector, and reconnect DC switch.
Others
No display
3.If the voltage is less than 70 V, please check the PV string configura-
tion.
4. If the voltage is higher than 180V and still no display please contact
local service office.
When sunlight is insuffcient, the PV inverter may continuously start and shut down due
to insufficient power generation by the PV panel, this will not damage the inverter. If the
problem still exists, please call the local service office.
Earth Fault Alarm
Inverters sold in Australia and New Zealand will also alarm as following when Isolation Fail occurs.
1. The buzzer in the inverter will sound for 1minute. If the problem persists, the buzzer willsound
every 30 min.
2. After adding the inverter to Power Sight, the alarm information will be emailed to the customers
via Power Sight.
33
Troubleshooting
7 Technical Parameters & Block Diagram

7.1 Technical Parameters

Technical Data
Input (DC)
Max. Input Power (W)
Max. Input Voltage (V)
MPPT Operating Voltage Range (V)
MPPT Voltage Range at Nominal Power (V)
Start-up Voltage (V)
Nominal Input Voltage (V)
Max. Input Current per MPPT (A)
Max. Short Circuit Current per MPPT (A)
Max. Backfeed Current to The Array (A)
Number of MPP Trackers
Number of Strings per MPPT
Output (AC)
Nominal Output Power (W)
Nominal Output Apparent Power (VA)
Max. AC Active Power (W)
Max. AC Apparent Power (VA)
Nominal Power at 40℃ (W)
Max Power at 40℃ (Including AC Overload) (W)
Nominal Output Voltage (V)
220, 3L/N/PE or 3L/PE
Output Voltage Range (V)
Nominal Output Frequency (Hz)
AC Grid Frequency Range (Hz)
Max. Output Current (A)
Max. Output Fault Current (Peak and Duration) (A/ms)
Inrush Current (Peak and Duration) (A/us)
Nominal Output Current (A)
Power Factor
Max. Total Harmonic Distortion
Efficiency
Max. Efficiency
Europen Efficiency
Protection
PV String Current Monitoring
PV Insulation Resistance Detection
Residual Current Monitoring
PV Reverse Polarity Protection
Anti-islanding Protection
AC Overcurrent Protection
AC Short Circuit Protection
AC Overvoltage Protection
DC Switch
DC Surge Protection
AC Surge Protection
AFCI
Remote Shutdown
PID Recovery
General Data
Operating Temperature Range (℃)
Relative Humidity
Max. Operating Altitude (m)
Cooling Method
Display
Communication
Communication protocols
GEP12-L-10
GEP15-L-10
15600
19500
800
800
200~650
200~650
360~600
360~600
180
180
370
370
30 or 26
30 or 26
*1
*1
37.5 or 33
37.5 or 33
*1
*1
0
0
3
3
2
2
12000
15000
12000
15000
12000
15000
12000
15000
12000
15000
12000
15000
220, 3L/N/PE or 3L/PE
220, 3L/N/PE or 3L/PE
176~242
176~242
50/60
50/60
47.5~51.5/57~61.8
47.5~51.5/57~61.8
47.5~51.5/57~61.8
31.5
40.0
160
160
60
60
31.5
39.4
~1 (Adjustable from 0.8 leading to 0.8 lagging)
<3%
<3%
98.0%
98.0%
97.7%
97.7%
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Type II
Type II
Optional
Optional
Optional
‐30~60 (60 °C for outdoor unconditioned with solar effects.)
0~100%
3000
Smart Fan Cooling
LED, LCD (Optional), WLAN+APP
RS485, WiFi, USB, PLC (Optional)
Modbus-RTU( SunSpec compliant)
GEP20-L-10
26000
800
200~650
360~600
180
370
30 or 26
*1
37.5 or 33
*1
0
3
2
20700
20700
20700
20700
20700
20700
176~242
50/60
54.5
160
60
54.3
<3%
98.0%
97.7%
34

Advertisement

Table of Contents
loading

Table of Contents