Installation Conditions; Inlet And Outlet; Bends In 2 Or 3 Dimensions - Honeywell VERSAFLOW MAG 4000 Quick Start Manual

Electromagnetic flow sensor
Table of Contents

Advertisement

VERSAFLOW MAG 4000

2.8 Installation conditions

2.8.1 Inlet and outlet

Figure 2-6: Recommended inlet and outlet
1 Refer to chapter "Bends in 2 or 3 dimensions"
2 DN
2
INFORMATION!
Sensors of type VN02 up to DN10:
The inlet and outlet sections are enclosed inside the sensor.

2.8.2 Bends in 2 or 3 dimensions

Figure 2-7: Inlet when using 2 and/or 3 dimensional bends upstream of the flowmeter
Inlet length: using bends in 2 dimensions:
INFORMATION!
2 Dimensional bends occur in a vertical or or or or horizontal plane only, while 3 Dimensional bends
occur in both vertical and
34-VF-25-51 iss.4 GLO May 18 US
5 DN; when having bends in 3 dimensions: 10 DN
and horizontal plane.
and
and
www.honeywellprocess.com