Damper Test; Digital Input Test; Temperature Probe Test - Electrolux ERF2500 Service Manual

Table of Contents

Advertisement

Pressing the push button „action" to switched on and off the component.
Pressing the push button „next" again to goes in the next phase.

4.6 Damper test

When the Service Mode starts, the damper is closed.
On the display is notified the index of the component.
LED on: damper is open
LED off: damper is closed
Pressing the push button „action" the damper is open and closed.
Pressing the push button „next" again to goes in the next phase.

4.7 Digital input test

Are defined to be tested every digital input of components connected to the electronic.
On the display is notified the index of the component.
LED on: Input is open
LED off: Input is closed
Pressing the push button „next", you active the next component.
The push button „action" is not used in these phases.
Pressing the push button „next" again to goes in the next phase.

4.8 Temperature probe test

SOE/TD - PR
7/8
599 73 16-18