Transportation And Storage; Technical Data - Husqvarna W 65P Operator's Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
The hoses are damaged or too long. The
There is no pump
hose has an incorrect diameter.
output or the pump
output is
The power of the engine is decreased
decreased
• Let the product become cool before you put it in
storage.
• Always use approved containers for storage and
transportation of fuel.
• Keep the product in a dry and frost-free area.
• Make sure that there are no leaks or fumes from the
product. Sparks or open flames, for example from
electrical devices or boilers, can start a fire.
• Put a cover on the product and safely attach the
product during transportation to prevent damage and

Technical data

Inlet/outlet dimension, m
Total level difference, m
Output pressure, MPa
Level difference for the suction hose, m
Engine model
Maximum discharge capacity, m/h
Fuel tank capacity, l
Net weight/Gross weight, kg
Oil tank capacity,
l
Engine oil quality
Type
Measured Sound Power Level, LWA dB (A)
Guaranteed Sound Power Level, LWA dB (A)

Transportation and storage

Technical Data
m
Select the correct hose for the operation. Refer to To
select the correct hoses for the operation on page 6.
.
Refer to The power of the engine is decreased on
page 9 .
accidents. Use an approved vehicle for transportation
of the product.
• Store the machine in a flat location and do not tilt or
turn over.
• Please clean the whole machine before storing for a
long time, and drain out the lubricating oil and fuel.
• Be careful when you move the product on or off a
vehicle for transportation. Use an approved ramp.
W 65P
63.5 / 50
55
0.5
7
WM170F/P
35
4.2
30/31.5
0.6
SAE 10W-30 SF min
Gasoline
104 dB (A)
107 dB (A)

Advertisement