Error Messages; Algo - AEG ARE i2.0x LF Manual

Table of Contents

Advertisement

Manual ARE i2.0x LF release V2

2.3.14 Error messages

Error messages and protocol errors are acknowledged by ARE i2.0x using an error code. The format is described below:
<NAK> '#' <error code> <CR>
Example error #02 (wrong parameter)
Hex:
15
ASCII:
<NAK>
The error code is comprised of a two digit ASCII coded number. Please note that for communication through ACM 9, the
appropriate reader number is preceding the error message.
The following table displays possible error messages:
Error code
"00"
"02"

2.3.15 ALGO

ALGO is used to activate one particular LF algorithm to be used in a particular installation.
Input format:
ALGO<SP>ALGO#<CR>
Example:
ALGO<SP>1<CR>
Hex:
41
ASCII:
'A'
Output (example): 1<CR>
Hex:
31
ASCII:
'1'
Above example activates algorithms 1
Implemented LF algorithms:
1 -
PSK1, Trovan
4 -
ASK 64 Bit Manchester
5 -
ISO 11784/85
6 -
Hitag1/HitagS
8 -
Hitag2
14 -
EM4305
23 -
HDX (TI)
29-
HDX (AEG ID)
32-
PSK1 and HDX in mixed population based on a 'gt' request