Table of Contents

Advertisement

Manual ARE i2.0x LF release V2

2.3.12 VSAVE

VSAVE – Save parameter permanently in ARE i2.0x flash memory
VSAVE is used to save parameters permanently in flash memory of ARE i2.0x to be available after power on.
Input format:
VSAVE <CR>
Hex:
56
ASCII:
'V'
Output (example): ACK<CR>
Hex:
41
ASCII:
'A'

2.3.13 INIT

INIT – Restore standard parameters. Command needs to be followed up by VSAVE in order to permanently store the
parameters.
Input format: INIT<CR>
Hex:
49
ASCII:
'I'
Output (example): ACK<CR>
Hex:
41
ASCII:
'A'
The following parameters are set:
TOR 50
MD 2
CID 0
CN 0
LSTB 01101
LGT 01111
Manual ARE i2.0x LF release V2.docx
53
41
'S'
'A'
43
4B
0D
'C'
'K'
<CR>
4E
49
'N'
'I'
43
4B
0D
'C'
'K'
<CR>
LRD 01001
LNRD 10001
LERR 10011
LED 1
LRT 30
LPA 00000
56
45
0D
'V'
'E'
<CR>
54
0D
'T'
<CR>
Version: 13
Page: 20 / 34