CONF IGURATION
MICROPROGRAM READABLE
o
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Figure 3 -3.
Control Configuration Switches
Table 3-1.
Control Configuration Switches
Switch
Switch Setting
Switch Function
NUnlber
Norrnal a
Other
Basic Logic Test (BLT)
0
Down (Execute BLT)
Up (Bypass BLT)
BLT Loop Control
1
Down (No Loop in BLT)
Up (Loop on BLT)
Select LA Port for Boot
2
Down (LA Port 2)
Up (LA Port 3)
Number of LAs in Subsystem
3
Down (Port 2)
Up (Ports 2 and 3)
Interval Time r Runout (ITRO)
4
Down (Enable ITRO)
Up (Inhibit ITRO)
Unassigned
5,6
Down, Down
(Not applicable)
Rotational Position Sensing (RPS)
7
Down (Disable)
Up (Enable)
Control Configuration
8, 9, 10
Down, Down, Down
(Non-Crossbar)
Down, Down, Up
(Crossbar)
(Not applicable)
Up, Down, Down
(Dual Control
as seen by
Software)
Automatic Retry (AR)
11
Down (Enable AR)
Up (Disable AR)
Unassigned
12. 13
Down, Down
(Not applicable)
Error Interrupt (EI)
14
Down (Bypass ITR)
Up (Branch to ITR)
Factory Test (FT) only
15
Down (Bypass FT)
Up (Factory Test)
aUnless set otherwise by Honeywell field engineer.
3-5.1
DB37