Philips 32PFL4007D/78 Service Manual page 16

Chassis tpm9.2l la
Table of Contents

Advertisement

EN 16
5.
TPM9.2L LA
Item Item value
10
CLR_TEMP_G
11
CLR_TEMP_B
12
AUTO_COLOR
13
ADC_GAIN_R
14
ADC_GAIN_G
15
ADC_GAIN_B
16
ADC_OFFSET_R
17
ADC_OFFSET_G
18
ADC_OFFSET_B
19
VIRGIN_MODE
20
E-Fuse
21
ORT_MODE
22
AGEING MODE
23
RESET_PBS_PWD
24
VIDEO_PWM_MEDIUM
25
VIDEO_PWM_MINIMUM
26
VIDEO_PWM_MAXIMUM
27
PWM_RATIO_BEST_PICTURE 100
28
PWM_RATIO_STD_TOP
29
PWM_RATIO_STD_BOTTOM
30
PWM_RATIO_BEST_POWER
31
VIDEO_STD_TH_HIGH
32
VIDEO_STD_TH_LOW
33
YPBPR_PHASE
34
AUD_LIMITER_MODE
35
AUD_THRESHOLD_BYTE1
36
AUD_THRESHOLD_BYTE2
37
AUD_THRESHOLD_BYTE3
38
AUD_GAIN_LINEIN
39
AUD_GAIN_HDMI
40
AUD_GAIN_ATV
41
AUD_GAIN_DTV
42
AUD_GAIN_USB
43
ESTICKER NVM 1
44
ESTICKER NVM 2
45
ESTICKER NVM 3
46
ESTICKER NVM 4
47
ESTICKER NVM 5
48
ESTICKER NVM 6
49
ESTICKER NVM 7
50
ESTICKER NVM 8
51
ESTICKER NVM 9
52
ESTICKER NVM 10
53
ESTICKER NVM 11
54
ESTICKER NVM 12
55
ESTICKER NVM 13
56
ESTICKER NVM 14
57
ESTICKER NVM 15
58
ESTICKER NVM 16
59
ESTICKER NVM 17
60
ESTICKER NVM 18
61
ESTICKER NVM 19
62
ESTICKER NVM 20
63
ESTICKER RESET
64
DIM_LIB_RESET
65
AQ_INDEX
66
Audio Test Mode
67
Audio Channel Type
68
Test Pattern
69
EDID UPDATE
70
TCON_GAMMA_UPDATE
71
DUMP PQ FROM TV
72
LOAD PQ to TV
73
DUMP AQ FROM TV
74
LOAD AQ to TV
75
EXIT_FACTORY
How to Exit the Factory mode
Use one of the following methods:
Select EXIT_FACTORY from the menu and press the "OK"
button.
2012-Mar-30
Service Modes, Error Codes, and Fault Finding
Default value
32"
37"
42"
47"
Description
128
Green colour temperature setting
128
Red colour temperature setting
Press OK
PC: any pattern that has black and white, YPbPr: SMPTE bar (colour bar), any timing.
0
Red ADC gain
0
Green ADC gain
0
Blue ADC gain
128
Red ADC offset
128
Green ADC offset
128
Blue ADC offset
Off/On
Use this to return the set to virgin mode. Depends whether the set has been used already.
On
E-fuse mode
Off
ORT mode
Off
Use this for ageing a new LCD panel
Press OK
Use this to reset the Child Lock
128
180
0
85
75
68
99
93
InValid
YPbPr Phase setting
2
Three modes, 0: off, 1: adaptive mode, 2: fixed mode
0
Limit threshold
0
Limit threshold
7
Limit threshold
2
Line-in audio gain
2
HDMI audio gain
2
Analogue TV audio gain
2
Digital TV audio gain
2
USB audio gain
15
Esticker data
0
Esticker data
64
Esticker data
124
Esticker data
91
Esticker data
0
Esticker data
0
Esticker data
0
Esticker data
0
Esticker data
0
Esticker data
16
Esticker data
31
Esticker data
17
Esticker data
7
Esticker data
0
Esticker data
0
Esticker data
0
Esticker data
0
Esticker data
0
Esticker data
0
Esticker data
Press OK
Reset the E-stickers
Press OK
Reset the Dimming
0
1
2
3
Audio Quality index
Off
Used for audio testing during production
2.0
Defines the installed speaker system
Press OK
With the "left" and "right" keys of the remote control various test patterns can be chosen
Press OK
Used to enter a new EDID codes into the NVM
Press OK
Press OK
Saves the picture quality data to a file "pq.bin" to the root of a FAT formatted USB memory stick
Press OK
Loads the picture quality data from a file "pq.bin" in to the TV
Press OK
Saves the audio quality data to a file "AQ.bin" to the root of a FAT formatted USB memory stick
Press OK
Loads the audio quality data from a file "AQ.bin" in to the TV
Press OK
Exits the Factory mode
Note: When the TV is switched "off" by a power interrupt, or
normal switch to "stand-by" while in the factory mode, the TV
will show up in "normal operation mode" as soon as the power
is supplied again. The error buffer will not be cleared.
back to
div. table

Advertisement

Table of Contents
loading

This manual is also suitable for:

4000 series32pfl4017g/7842pfl4007g/78

Table of Contents