442 Parameters
No.
Name/Value
99.19
Sine filter
capacitance
0.00 ... 100000.00
µF
200

200 Safety

This group contains parameters related to the optional FSO-xx safety functions module. For details, refer to
the documentation of the FSO-xx module.
206
207
208
209
206 I/O bus
configuration
207 I/O bus service
208 I/O bus diagnostics
209 I/O bus fan
identification
These groups contain parameters related to the distributed I/O bus, which is used with some drives for
monitoring the cooling fans of the cabinet system. For details, refer to CIO-01 I/O module for distributed I/O
bus control user's manual (3AXD50000126880 [English]).
Description
Defines the capacitance of a custom sine filter, ie. when
parameter
95.15 Special HW settings
If the capacitors are star/wye-connected, enter the
capacitance of one leg into the parameter.
Drive
Sine filter
If the capacitors are delta-connected, multiply the capacitance
of one leg by 3 and enter the result into the parameter.
Drive
Sine filter
Note: For an ABB sine filter
this parameter is set automatically and should not be
adjusted.
Capacitance of custom sine filter.
FSO-xx settings.
Distributed I/O bus settings.
These groups are only visible with a BCU control unit.
bit 3 is activated.
C
C
C
99.19
C
C
99.19
C
(95.15 Special HW settings
Def/FbEq16
-
M
3~
= C
M
3~
= 3 × C
bit 1),
100 = 1 µF