D2D And Ddcs Receive Data - ABB ACS880-x04 Firmware Manual

Primary control program
Table of Contents

Advertisement

No.
Name/Value
LSU CW
DC voltage
reference
Reactive power
reference
Other
61.152 INU-LSU data set
10 data 2 sel
61.153 INU-LSU data set
10 data 3 sel
61.201 INU-LSU data set
10 data 1 value
0...65535
61.202 INU-LSU data set
10 data 2 value
0...65535
61.203 INU-LSU data set
10 data 3 value
0...65535
62
62 D2D and DDCS
receive data
62.01
M/F data 1
selection
None
CW 16bit
Ref1 16bit
Ref2 16bit
Other
62.02
M/F data 2
selection
Description
Control word for the supply unit.
94.20 DC voltage reference
94.30 Reactive power reference
Source selection (see
Terms and abbreviations
Preselects the data to be sent as word 2 of data set 10 to the
other converter.
See also parameter
61.202 INU-LSU data set 10 data 2
For the selections, see parameter
10 data 1
sel.
Preselects the data to be sent as word 3 of data set 10 to the
other converter.
See also parameter
61.203 INU-LSU data set 10 data 3
For the selections, see parameter
10 data 1
sel.
Displays (in integer format) the data to be sent to the other
converter as word 1 of data set 10.
If no data has been preselected by
10 data 1
sel, the value to be sent can be written directly into
this parameter.
Data to be sent as word 1 of data set 10.
Displays (in integer format) the data to be sent to the other
converter as word 2 of data set 10.
If no data has been preselected by
10 data 2
sel, the value to be sent can be written directly into
this parameter.
Data to be sent as word 2 of data set 10.
Displays (in integer format) the data to be sent to the other
converter as word 3 of data set 10.
If no data has been selected by
data 3
sel, the value to be sent can be written directly into this
parameter.
Data to be sent as word 3 of data set 10.
Mapping of data received through the DDCS link.
See also parameter group
(Follower only) Defines a target for the data received as word
1 from the master through the master/follower link.
See also parameter
62.25 MF data 1
None.
Control Word (16 bits)
Reference REF1 (16 bits)
Reference REF2 (16 bits)
Source selection (see
Terms and abbreviations
(Follower only) Defines a target for the data received as word
2 from the master through the master/follower link.
See also parameter
62.26 MF data 2
For the selections, see parameter
(page 410).
(page 410).
on page 114). -
61.151 INU-LSU data set
61.151 INU-LSU data set
61.151 INU-LSU data set
61.152 INU-LSU data set
61.153 INU-LSU data set 10
60 DDCS
communication.
value.
on page 114). -
value.
62.01 M/F data 1
Parameters 381
Def/FbEq16
22
24084
24094
DC voltage
reference
value.
Reactive
power
reference
value.
0
0
0
None
0
1
2
3
None
selection.

Advertisement

Table of Contents
loading

Table of Contents