Zennio MINiBOX 40 v3 Quick Start Manual

Zennio MINiBOX 40 v3 Quick Start Manual

Multifunction actuator with 4 outputs (16 a) with knx secure

Advertisement

Quick Links

Multifunction actuator with 4 outputs (16 A) with KNX Secure
ZIOMN40V3
FEATURES
4 configurable outputs: shutter channels (up to 2), individual outputs (up
to 4) and 2-pipe fan coil control (up to 1)
Outputs suitable for capacitive loads, maximum 140 µF
Supports KNX Data Secure
Manual output operation with push button and LED status indicator
10 logic functions
Output timing
Total data saving on KNX bus failure
Integrated KNX BCU (TP1-256)
Dimensions 67 x 90 x 36 mm (2 DIN units)
DIN rail mounting according to IEC 60715 TH35, with fixing clamp
Possibility of connecting different phases in adjacent outputs
Conformity with the CE, UKCA, RCM directives (marks on the right side)
1. Upper outputs
4. Programming/test button
Programming/Test button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe
mode. If this button is held for more than 3 seconds, the device enters the test mode. In order to perform a KNX Secure factory reset, while the device
is in safe mode, press the button for 10 seconds until the programming LED changes its state.
Programming/Test LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. The test mode is
indicated by the green color. During the start-up (reset or after KNX bus failure) and if the device is not in safe mode, it starts a blue blinking sequence.
GENERAL SPECIFICATIONS
CONCEPT
Type of device
Voltage (typical)
Voltage range
KNX supply
Maximum
consumption
Connection type
External power supply
Operation temperature
Storage temperature
Operation humidity
Storage humidity
Complementary characteristics
Protection class / Overvoltage category
Operation type
Device action type
Electrical stress period
Degree of protection / Pollution degree
Installation
Minimum clearances
Response on KNX bus failure
Response on KNX bus restart
Operation indicator
Weight
PCB CTI index
Housing material / Ball pressure test temperature
¹ Maximum consumption in the worst-case scenario (KNX Fan-In model).
© Zennio Avance y Tecnología S.L.
2. Programming/test LED
5. Output control button
Voltage
29 VDC (typical)
24 VDC¹
Edition 1
DESCRIPTION
Electric operation control device
29 VDC SELV
21-31 VDC
mA
4
10
Typical TP1 bus connector for 0.8 mm Ø rigid cable
Not required
0 .. +55 °C
-20 .. +55 °C
5 .. 95%
5 .. 95%
Class B
II / III (4000 V)
Continuous operation
Type 1
Long
IP20 / 2 (clean environment)
Independent device to be mounted inside electrical panels with DIN rail (IEC
60715)
Not required
Data saving according to parameterization
Data recovery according to parameterization
The programming LED indicates programming mode (red) and test mode
(green). Each output LED indicates its status
91 g
175 V
PC FR V0 halogen free / 75 °C (housing) - 125 °C (connectors)
Further information
MINiBOX 40 v3
TECHNICAL DOCUMENTATION
1
2 3
Figure 1: MINiBOX 40 v3
3. KNX Connector
6. Output status LED indicator
mW
116
240
www.zennio.com
6
5
4
Page 1/2

Advertisement

loading

Summary of Contents for Zennio MINiBOX 40 v3

  • Page 1 DIN rail mounting according to IEC 60715 TH35, with fixing clamp • Possibility of connecting different phases in adjacent outputs • Conformity with the CE, UKCA, RCM directives (marks on the right side) Figure 1: MINiBOX 40 v3 1. Upper outputs 2. Programming/test LED 3. KNX Connector 4. Programming/test button 5.
  • Page 2 • The WEEE logo means that this device contains electronic parts and it must be properly disposed of by following the instructions at https://www.zennio.com/en/legal/weee-regulation. • This device contains software subject to specific licences. For details, please refer to https://zennio.com/licenses. © Zennio Avance y Tecnología S.L.

This manual is also suitable for: