SWITCH
OFF
ON
NUMBER
DIP SWITCH (WHITE AREAS DENOTE SWITCH HANDLES)
POSITION 7: NO FUNCTION
POSITIONS 2-6:
POSITION 1: ENABLES/DISABLES COVER TAMPER. ON = TAMPER DISABLED,
4204
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
Must be connected to a
power-limited source.
Supervised
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED FOR
DETAILS REGARDING THE LIMITATIONS OFTHE ENTIRE ALARM SYSTEM.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes
or modifications could void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions,
may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance
with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
If using an indoor antenna, have a quality outdoor antenna installed.
Reorient the receiving antenna until interference is reduced or eliminated.
Move the radio or television receiver away from the receiver/control.
Move the antenna leads away from any wire runs to the receiver/control.
Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1)
Cet appareil ne doit pas causer d'interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception
indésirable.
ÊN8909V4†Š
N8909V4 10/12 Rev. B
DIP SWITCH SETTINGS
0
1
2
3
4
5
6
8
9 10 11 12 13 14 15
7
2
ON — ON — ON — ON — ON — ON — ON — ON —
3
ON ON — — ON ON — — ON ON — — ON ON — —
4
ON ON ON ON — — — — ON ON ON ON — — — —
5
ON ON ON ON ON ON ON ON — — — — — — — —
ON ON ON ON ON ON ON ON
6
ON ON ON ON ON ON ON ON
DETERMINE 4204'S ADDRESS: CONTROL'S INSTRUCTIONS SPECIFY ADDRESS
TO USE. "0" ADDRESS SETTING SHOWN (AS SHIPPED).
OFF = TAMPER ENABLED. SHOWN DISABLED AS SHIPPED.
(SHOWN "OFF")
4-PIN TOUCHPAD PLUG
EITHER OR BOTH
CAN BE USED
TB1
13
14
15
16
YEL
DATA IN FROM CONTROL
BLK
(–) GROUND
GRN
DATA OUT TO CONTROL
RED
(+) 12VDC
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
©
Copyright
2008 Honeywell International Inc.
www.honeywell.com/security
4204 ADDRESS SETTINGS
("—" means "OFF")
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
ON — ON — ON — ON — ON — ON — ON — ON —
ON ON — — ON ON — — ON ON — — ON ON — —
ON ON ON ON — — — — ON ON ON ON — — — —
ON ON ON ON ON ON ON ON — — — — — — — —
— — — — — — — —
RELAY
C
4
NC
TYPICAL
NO
C
RELAY
3
NC
NO
C
RELAY
2
NC
NO
C
RELAY
1
NC
NO
TB2
4204 CONNECTIONS
— — — — — — — —
4204-01-V1
If switching power
through a relay, the
power must be from a
power-limited source.
Relays are programmable
but outputs are not
supervised.
4204-02-V2

Advertisement

loading