D6600/D6100IPv6
This document supplements the Conettix D6600/D6100IPv6 Installation and Operation Guide
(P/N: 4998122704-08).
1.0
Network Ethernet Module
In the D6600/D6100IPv6 Installation and Operation Guide (4998122704-08), all references to
Network Ethernet Module are the ITS-D6686-UL and its associated documentation (the Conettix
D6686 Ethernet Network Adapter Installation Guide [F01U269888-01]).
2.0
Additional Printer Specification
In Section 6.0 Printer Specifications of the D6600/D6100IPv6i Installation and Operation Guide
(4998122704-08), include the following specification:
The printer must be installed in the same room as the D6600/D6100IPv6.
3.0
Installation
3.1
All Installations
In Section 7.0 Installation of the D6600/D6100IPv6 Installation and Operation Guide (4998122704-
08), include the following installation requirements and notes:
Install the D6600/D6100IPv6 Communications Receiver/Gateway according to the National
Electrical Code (NFPA 70), the National Fire Alarm Code (NFPA 72), and the local Authority
Having Jurisdiction (AHJ).
UL Standard 827 requires that any central station listed for NFPA 72, Central Station Protective
Signaling, UL Central Station Burglary or Police Station Connect Service must have a redundant
receiver on the premises to use if the primary receiver malfunctions.
The D6640 Telephone Line Card is not intended for new installations, but is suitable for existing or
retrofit sites.
Equipment between Ethernet Interface Modules and the D6600/D6100IPv6 must be UL Listed
Information Technology Equipment (ITE).
A "COMM FAIL" message might indicate a compromise attempt.
To meet requirement UL 1610, Section 63.1: The number of separate signals on a single channel is
limited to 1000. Exception: There is no limit to the number of signals if the central-station equipment
is completely duplicated by standby equipment and a switchover can be accomplished in not more
than 90 sec without loss of signals during this period.
The D6100IPv6 was tested by UL at 120VAC, 60 Hz.
UL864 & UL1610 Installation
Supplement
Aug 2012

Advertisement

loading

Summary of Contents for Bosch D6600

  • Page 1 Network Ethernet Module are the ITS-D6686-UL and its associated documentation (the Conettix D6686 Ethernet Network Adapter Installation Guide [F01U269888-01]). Additional Printer Specification In Section 6.0 Printer Specifications of the D6600/D6100IPv6i Installation and Operation Guide (4998122704-08), include the following specification: •...
  • Page 2 SC9002 printer connected. Install the D6600/D6100IPv6 according to UL Standard 827 for Central Station Burglar Alarm Systems. Use the D6600/D6100IPv6 in a central station that has backup AC power (according to UL 827) to supervise certificated accounts. UL864 & UL1610 Installation Supplement ©...
  • Page 3 GlobTek, Inc. Model DA-42-18L Transformer Plug the D6600 AC cord or the D6100IPv6 AC transformer into an outlet inside the rack only if the outlet is wired according to Article 760 of the NEC. Rack mounting is required (according to NFPA 72-2002 4.4.1.4.2.1) to meet the mechanical protection requirement when using the type of AC cord...
  • Page 4 Specifications In Section 16.0 Specifications of the D6600/D6100IPv6 Installation and Operation Guide (4998122704-08), include the following specification: D6100IPv6 Power AC Nominal Operating Range Use the GlobTek, Inc. Model DA-42-18L transformer. Input Input voltage: 120VAC 60Hz 0.44 A maximum © Bosch Security Systems, Inc., 2012...