12.6

Software update

12.6.1

Firmware

i
The firmware (software) can be updated by way of
a PS2 stick. Further information can be obtained
from customer service.
12.6.2

Vehicle database

i
The vehicle database can be updated annually by
way of a PS2 stick. Further information can be
obtained from customer service.
!
Do not switch off ACS 810 during update process.
!
Observe the ACS 810 menu prompting.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "DATABASE UPDATE" with o u and confirm
with E.
INSERT THE KEY
is displayed.
5. Remove plastic cover (input PS2 stick) between
menu key and stop key.
6. Insert PS2 stick.
7. Activate or deactivate with o u and confirm with E.
 The update is performed.
"
Data base is updated.
i
Return with <Stop>.
12.7

Replacing printer paper

!
Avoid excessive force so as not to damage the
printer cover.
1. Open the printer cover.
2. Remove old printer paper roll.
3. Fit new printer paper roll.
Fig. 7:
Replacing printer paper
1 Printer paper
Robert Bosch GmbH
is displayed.
1
Maintenance | ACS 810 | 61 |
4. Close the printer cover.
i
To cut the printer paper correctly, pull the paper
towards the tear bar from one side to another.
12.8
Periodic check of the non-condensable
gas purge valve
CAUTION: Only qualified technicians who
are authorized to use refrigerants may
carry out this procedure.
Wear personal protective equipment
(glasses and gloves).
Do not go in front of the discharge flow.
The valve does not require adjustment or
lubrication. Do not tamper with it in any
way.
Fig. 8:

Periodic check of the non-condensable gas purge valve

1 Non-condensable gas purge valve
i
To ensure that the valve remains in good working
condition, periodically make it trip by pulling the
metal ring at the top.
i
While doing this, make sure that the pressure in the
cylinder is at least 8–10 bar.
i
The valve should open sharply and then close
firmly as soon as the metal ring is released.
!
This action must be quick, and do not repeat it
until only non-condensable gas is purged, with no
refrigerant.
i
The frequency depends on the valve condition,
and specifically on its cleanliness, which normally
depends on whether there are residues in the
cylinder or not.
en