IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity
for Industrial Environments
IEC 61850-3
Communication Networks and Systems in Substations – Part 3: General Require-
ments
NEMA TS-2
Traffic Controller Assemblies with NTCIP Requirements
6.2
EMC and Environmental Type Tests
The RUGGEDCOM RS900F has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test
61000-4-2
61000-4-3
61000-4-4
61000-4-5
61000-4-6
RUGGEDCOM RS900F
Installation Manual, 02/2020, C79000-G8976-1350-04
All manuals and user guides at all-guides.com
Description
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
IEC
Surge
IEC
Induced (Conducted) RFI
6.2 EMC and Environmental Type Tests
Test Levels
Enclosure
± 8 kV
Contact
Enclosure Air
± 15 kV
Enclo-
20 V/m
sure Ports
Signal Ports
± 4 kV @ 2.5 kHz
DC Pow-
± 4 kV
er Ports
AC Pow-
± 4 kV
er Ports
Earth
± 4 kV
Ground Ports
Signal Ports
± 4 kV Line-to-Ground
± 2 kV
DC Pow-
± 2 kV Line-to-Ground
er Ports
± 1 kV Line-to-Line
AC Pow-
± 4 kV Line-to-Ground
er Ports
± 2 kV Line-to-Line
Signal Ports
10 V
DC Pow-
10 V
er Ports
AC Pow-
10 V
er Ports
Earth
10 V
Ground Ports
Certification
Severi-
ty Levels
4
4
x
4
4
4
4
3
4
3
3
3
3
35