Item no. 027966
Configuration tool for reader series luminAXS
LEGIC operating mode for LEGIC readers "Insertic"
Table of Contents
1. Application ..................................................................................3
2. Required programming software ..............................................3
3. Operating voltage .......................................................................3
4. Initial start-up configuration tool ..............................................3
5. Connection diagrams .................................................................3
5.1 configuration tool ..................................................................3
5.2 Reader ..................................................................................3
5.2.1 luminAXS reader proX ................................................3
5.2.2 luminAXS reader mifare..............................................4
5.2.3 LEGIC reader "Insertic" RS-485 .................................4
6. Start-up reader ............................................................................4
7. Technical Data.............................................................................4
1.
Application
Depending on the application a reader uses, it may be necessary to
change the default parameters (state on delivery)
The configuration tool USB allows you to transfer parameterizations
directly from the PC to the readers (also Clock/Data readers).
2.
Required programming software
The parameterisation of the readers is carried out with the software
tool "IQ DeviceInstaller".
You can find the IQ DeviceInstaller on our homepage in the download
area. Instructions are enclosed.
3.
Operating voltage
Use a laboratory power supply with 12 V DC and 500 mA current
limited as operating voltage for the configuration tool USB and the
reader.
4.
Initial start-up configuration tool
Do not connect the configuration tool USB to the PC / laptop yet.
In order to automatically install the driver software required for
operation during commissioning, the following setting must be present
in the Windows Control Panel (correct if necessary):
Control Panel –> System –> Advanced System Setting –> Hardware
–> Device Installation Settings
–> Download Windows Driver Software?
"Yes, automatic download" must be enabled.
Connect the configuration tool to the operating voltage.
Connect the interface converter of the configuration tool to the USB
interface on the PC / laptop.
The required driver is automatically installed now. This can take a few
minutes.
P30739-36-002-01
2017-11-16
5.
Connection diagrams
5.1
Connect configuration tool
Connect the configuration tool to the operating voltage.
Connect the interface converter of the configuration tool to the USB
interface on the PC / laptop.
configuration tool USB
Programmierbox USB
Art.-Nr./Item no. 027966
NOVAR GmbH
Johannes-Mauthe-Straße 14
72458 Albstadt/Germany
5.2
Readers
The pin connection sequence corresponds to the plug
connections of the luminAXS readers in the state of delivery.
If the plug-in connections are already removed, use the screw-
type terminals provided for the connection.
It is not possible to operate 2 readers at the same time!
5.2.1
luminAXS reader proX
RS-485 interface
RS-485
Clock/Data interface
Clock/Data
After applying the operating voltage, the 3 LEDs on the reader flash
for 5 seconds.
Within this time, it is possible to connect to the IQ DeviceInstaller.
For details, see the instructions for the IQ DeviceInstaller.
+12 V DC
0 V
RS-485
USB
Interface converter
PC/Laptop
Wiegand
RS485
RD
+UB
1
BU
0V
2
YE
A
3
WH
B
4
BK
Syn.
5
Wiegand
RS485
RD
1
+UB
BU
2
0V
YE
3
Data 1 (CLK)
WH
4
Data 2 (Data)
BK
Syn.
5
GN
6
LED green
BN
LED yellow
7
PK
LED red
8
D
Subject to change