INSTALLATION OPTIONS
®
The THX9321 Prestige
2.0 thermostat is wired directly to the equipment. The THX9421 Prestige
with the Equipment Interface Module or with a TrueZONE Wireless Adapter.
If using the Equipment Interface Module, see "Installing Equipment Interface Module (if used)" beginning on page 10.
If using a TrueZONE wireless adapter, follow the installation instructions that came with the TrueZONE, and go to
"Selecting Thermostat Location" beginning on page 12.
WIRED DIRECTLY TO E
WIRED DIRECTLY TO EQUIPMENT
THX9321 THERMOSTAT
RedLINK TO EQUIPMENT INTERFACE MODULE
THX9421 THERMOSTAT –
RedLINK TO TrueZONE WIRELESS ADAPTER
THX9421 THERMOSTAT –
Guidelines for Installing RedLINK
Devices
When installing more than one Thermostat and
Equipment Interface Module, mount the Equip-
ment Interface Modules at least 2 feet apart for
best RedLINK performance. No minimum distance
is required between the Thermostats if the Thermo-
stat is linked to an Equipment Interface Module.
When the Thermostat is wired directly to the equip-
ment (No Equipment Interface Module and No
TrueZONE Wireless Adapter), mount the Thermo-
stats at least 2 feet apart for best RedLINK perfor-
mance.
To determine if a RedLINK device will communicate
properly in the installed location, during the con-
nection process, press and quickly release the con-
nect button on the RedLINK device at the desired
mounting location. If the RedLINK device connects,
THX9321 PRESTIGE
OR
TM
2 WIRES FOR POWER
OR
TM
2 WIRES FOR POWER
9
®
2.0 AND THX9421 PRESTIGE
then it will work reliably during normal operation. If
the RedLINK device does NOT connect, try a new
location. During the connection process, the signal
is sent at low power and during normal operation
the signal is sent at high power.
To connect a RedLINK device, make sure to press
and quickly release the connect button on the
RedLINK device. Press and holding the connect
button down too long will not allow the device to
connect.
If you link the Thermostat to the TrueZONE Wire-
less Adapter, you will NOT be able to do the follow-
ing: control humidification, dehumidification or
ventilation, setup a program schedule remotely
from a computer, smart phone or tablet, work with
the Wireless Indoor Sensor, Entry / Exit Remote or
the Vent and Filter Boost Remote. To use these fea-
tures, wire the Thermostat directly to the zone
panel or use an Equipment Interface Module.
If you are using a RedLINK device from a previous
installation, you must reset the device first before
you re-connect it to the new Thermostat/Equip-
ment Interface Module. See page 136 for more
information.
®
IAQ WITH EIM
®
IAQ thermostat is used
MCR34631
68-0311—07

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prestige iaq with eim thx932

Table of Contents