5. PRODUCT INSTALLATION

Important notes and advice:
- To make the most of your intercom panel, we recommend configuring it (RFID, for 1 or 2
families, 1 or 2 intercoms, loudspeaker volume) before final installation. To do this, you will
need to connect it on a table, to ensure that the settings have been configured correctly.
- If you test your product before installing it, ensure that you do not test it with the intercom
panel and the monitor in the same room to avoid the videophone emitting a shrill noise
(feedback).
Do not expose the camera lens to direct sunlight or a reflective surface.
- Do not expose the intercom panel to any source of light at night as this will inhibit
activation of the twilight sensor.
- We recommend running the cables through a protective sheath to protect them against
breakage and bad weather.
- For the WelcomeEye Connect version, to take full advantage of your monitor's WiFi
function, we recommend you check that your 2.4 GHZ frequency WiFi network is accessible
from where it is installed.

1. Wiring

In order to avoid the risk of interference and malfunction, do not pass the wire for your
videophone through the same sheath as the electrical wires.
Warning:
Do not under any circumstances double wires to increase the wire size.
a. Connecting the videophone (monitor, intercom panel and camera)
Wires to be used:
long.
The cable connecting the devices must be a single piece (no wago or domino connector
systems)
- Ensure proper connection of the wires, following one of the wiring diagrams depending
on the desired configuration.
- Be sure to refer to the labelling on the back of the monitor and the back of the intercom
panel.
- Configure the switches on the back of the intercom panel as well as the monitor interface
according to the chosen configuration (see section 2 intercom configuration).
b. Connecting a gate motor
- The intercom provides a dry contact (without power) to be connected to the push button
control of the automatic opener.
- Connect it directly to terminals 5 and 6 at the back of the intercom panel (no need to
observe polarity).
- The function can only be used if the respective intercom panel video is displayed.
c. Connecting a strike plate or electric lock
Important:
The electric strike plate or lock that you install must be equipped with a
mechanical memory. The strike plate current cannot exceed 1.1A.
- Connect it directly to terminals 7 and 8 at the back of the intercom panel (no need to
observe polarity).
GB5
2 wires 0.75 mm
2
WelcomeEye Connect Pro / V5
up to 80 m long or 2 wires 1.5 mm
up to 120 m