- The dry contact function can only be used if the respective intercom panel video is
displayed.
2. Configuring the intercom (see fig. 1, fig. 2 or fig. 3)
a. Configuring the intercom number:
Place switch 2 on the left on intercom no. 1 and on the right on intercom no. 2.
b. Configuring the number of families:
Place switch 1 on the left for single family mode and on the right for two family mode.
c. Intercom volume settings:
Turn the volume control with a Phillips head screwdriver to adjust the intercom volume.
Turn clockwise to increase the volume. Turn anti-clockwise to decrease it.
d. Configuration of the RFID function:
The RFID function enables openings to be managed using badges.
1) Programming (or resetting) the administrator badges:
(The monitor must not be in communication with the intercom panel when configuring
badges)
When switching on the device for the first time, the badges must be configured in the
following order:
(Be sure to program the badges one by one. To avoid any problems, do not hold all the
badges in your hand)
1. Short press the reset button at the back of the intercom panel. The intercom panel will
emit six short beeps.
2. Swipe the yellow administrator badge, one short beep confirms the programming.
3. Swipe the blue badge, one short beep confirms the programming.
4. Swipe the red badge, one long beep confirms that the administration badges have been
programmed.
2) Add one or more user badges:
1. Swipe the blue badge, four long beeps confirm the activation of the programming mode.
2. Swipe all user badges (grey) to be activated; one short beep confirms the programming
of every badge presented.
3. Once all of the badges have been programmed, wait 10 seconds. One long beep confirms
the end of the programming process.
3) Remove one or more user badges:
1. Swipe the badge (red); 4 long beeps confirm the activation of the programming mode.
2. Swipe all user badges (grey) to be deactivated; one short beep confirms the deactivation
of every badge presented.
3. Once all badges have been deactivated, wait 10 seconds. One long beep confirms the
end of the programming process.
4) Remove all user badges:
1.
Swipe the administrator badge (blue); 4 short beeps confirm the activation of the
administration mode.
2. Swipe 1 user badge (grey) that has already been added; one short beep indicates that all
user badges have been deactivated.
5) Using the badges:
To open the electric strike plate, quickly swipe your pre-programmed grey user badge on
the RFID reading field. One short beep confirms the opening of the electric strike plate.
WelcomeEye Connect Pro / V5