Answer To A Parameter Input; Answer To A Parameter Request; Empty Input Line; Capital And Small Letters - AEG ARE i5 MTL Manual

Rfid reader rs 232
Table of Contents

Advertisement

Answer to a parameter input

After input of a valid parameter value, the reader answers with the new parameter value and a <CR>. The
new parameter value has been saved. Example:
Command:
Answer:
After input of a invalid parameter value, the reader answers with the actual valid parameter:
Command:
Answer:

Answer to a parameter request

Parameter values can be read by using the parameter command without a parameter value. Example:
Command:
Answer:

Empty input line

If only a <CR> sent, the reader answers with a <CR>. Example:
Command:
Answer:

Capital and small letters

The reader interface does not act case sensitive. Captial and small letters are treated the same.

Carriage return

The reader does not send a line feed <LF>. Our terminal programs replace the <CR> by a <CR><LF>. Some
programs like the "HyperTerminal" provide this as an option.
--------------------------------------------------------------------------12/21------------------------------------------------------------------------------------
MD <SP> 2 <CR>
2 <CR>
MD <SP> 4 <CR>
2 <CR>
MD <CR>
2 <CR>
<CR>
<CR>