Preferred Symbology Time-out

Once you have enabled Preferred Symbology and entered the high and low priority
symbologies, you must set the time-out period. This is the period of time the
scanner will search for a high priority barcode after a low priority barcode has been
encountered. Scan the barcode below, then set the delay (from 1-3,000
milliseconds) by scanning digits from the
222, then scanning Save. Default = 500 ms.

Preferred Symbology Default

Scan the barcode below to set all Preferred Symbology entries to their default
values.

Output Sequence Overview

Output Sequence Editor

This programming selection allows you to program the scanner to output data
(when scanning more than one symbol) in whatever order your application
requires, regardless of the order in which the barcodes are scanned. Reading the
Default Sequence symbol programs the scanner to the Universal values, shown
below. These are the defaults. Be certain you want to delete or clear all formats
before you read the Default Sequence symbol.
Note: To make Output Sequence Editor selections, you'll need to know the code I.D., code
length, and character match(es) your application requires. Use the Alphanumeric
symbols from the
trigger while reading each barcode in the sequence.

To Add an Output Sequence

1. Scan the Enter Sequence symbol (see
2. Code I.D.
54
Programming
On the
Symbology Charts
to apply the output sequence format. Locate the Hex value for that symbology
Programming
Preferred Symbology Time-out
Preferred Symbology Default
Chart, beginning on page 222. You must hold the
Require Output
on page 211, find the symbology to which you want
Chart, beginning on page
Sequence, page 57).