Honeywell Xenon 1900 Quick Start Manual

Honeywell Xenon 1900 Quick Start Manual

Corded area-imaging scanner
Hide thumbs Also See for Xenon 1900:

Advertisement

Xenon™ 1900
Corded Area-Imaging Scanner

Quick Start Guide

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Xenon 1900

  • Page 1: Quick Start Guide

    Xenon™ 1900 Corded Area-Imaging Scanner Quick Start Guide...
  • Page 2: Getting Started

    Note: Refer to your user’s guide for information about cleaning your device. For localized language versions of this document, go to www.honeywellaidc.com. Getting Started Turn off computer’s power before connecting the scanner, then power up the computer once the scanner is fully connected. Power Supply Assembly (if included)
  • Page 3 USB Connection Keyboard Wedge Connection...
  • Page 4 RS232 Serial Port Connection RS485 Connection...
  • Page 5: Reading Techniques

    Reading Techniques The view finder projects an aiming beam that should be centered over the bar code, but it can be positioned in any direction for a good read. Hold the scanner over the bar code, pull the trigger, and center the aiming beam on the bar code.
  • Page 6 RS485 Interface The RS485 interface defaults to port 5B. If you have an IBM POS terminal using port 9B, scan the appropriate code below to program the terminal, then power cycle the cash register. IBM Port 9B HHBCR-1 Interface IBM Port 9B HHBCR-2 Interface Note: For additional RS485 interface selections, see the User’s Guide for your product at our...
  • Page 7: Keyboard Country

    Keyboard Country Scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) from page 11, then the Save bar code to program the keyboard for your country. As a general rule, the following characters are not supported by the scanner for countries other than the United States: @ | $ # { } [ ] = / ‘...
  • Page 8 Trigger The following bar codes will allow you to use the scanner in Manual Trigger - Normal Mode (need to press the trigger to read) or Presentation mode (the scanner is activated when it “sees” a bar code). Manual Trigger - Normal (Default) Presentation Mode Streaming Presentation™...
  • Page 9: Add Code Id Prefix To All Symbologies

    Suffix If you want a carriage return after the bar code, scan the Add CR Suffix bar code. To add a tab after the bar code, scan the Add Tab Suffix bar code. Otherwise, scan the Remove Suffix bar code to remove the suffixes. Add CR Suffix Add Tab Suffix Remove Suffix...
  • Page 10: Function Code Transmit

    Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in your User’s Guide. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted.
  • Page 11 5. Length: scan 9999 for any length bar code. 6. Editor commands: use the Programming Chart that follows. 7. Scan Save to save your entries. Enter Data Format Clear All Data Formats Save...
  • Page 12: Programming Chart

    Programming Chart...
  • Page 13 Save...
  • Page 14: Technical Assistance

    Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (21) 3535-9100 Fax: +55 (21) 3535-9105 E-mail: brsuporte@honeywell.com...
  • Page 15 Europe, Middle East, and Africa Telephone: +31 (0) 40 7999 393 Fax: +31 (0) 40 2425 672 E-mail: hsmeurosupport@honeywell.com Hong Kong Telephone: +852-29536436 Fax: +851-2511-3557 E-mail: aptechsupport@honeywell.com Singapore Telephone: +65-6842-7155 Fax: +65-6842-7166 E-mail: aptechsupport@honeywell.com China Telephone: +86 800 828 2803 Fax: +86-512-6762-2560 E-mail: aptechsupport@honeywell.com...
  • Page 16: Product Service And Repair

    Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product.
  • Page 17: Limited Warranty

    Hong Kong Telephone: +852-29536436 Fax: +851-2511-3557 E-mail: apservice@honeywell.com Singapore Telephone: +65-6842-7155 Fax: +65-6842-7166 E-mail: apservice@honeywell.com China Telephone: +86 800 828 2803 Fax: +86-512-6762-2560 E-mail: apservice@honeywell.com Japan Telephone: +81-3-3839-8511 Fax: +81-3-3839-8519 E-mail: apservice@honeywell.com Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.honeywellaidc.com.
  • Page 18 Honeywell to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
  • Page 20 Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com NG2D-QS Rev A 3/10...