E N G L I S H
Environmental Class II
References:
Output A and Output B:
Each output allows a maximum of 10x Wireless Inputs and 6x Wireless
Keyfobs to be learnt. The relays will wire directly to an input on the
control panel (normally open or normally closed).The outputs should be
connected to an input programmed according to the device learnt (e.g.
Keyswitch input for keyfobs, or Intruder input for wireless devices)
Fault Output:
This output will activate if there are any of the following faults:
Low Battery / Jamming / Supervision / Tamper
The output should be connected to an input programmed as 'Fault'.
Arm / Disarm Status:
In order to receive alarm events from learned devices, the 'ARM' terminal
should be connected to an output that monitors the ARM/DISARM status of
the control panel. The shown dip switch is used to select 0v or 12v applied
when the control panel is armed.
Learning Inputs:
It is recommended that all inputs are learnt to one output (e.g. OUTPUT A)
and all keyfobs are learnt to the other output (e.g. OUTPUT B) -A dot next
to the letter/number indicates that an Input is connected to OUTPUT B.
Learning Keyfobs:
If learning keyfobs, the control panel input should be programmed as a
keyswitch.
Signal Strength Indicator:
Shows the following for each input learned:
A
B
C
':
'
':Excellent. '
':Good. '
':Bad. '
Waiting for response/out of range
Event Log /History: (Events display in realtime AND in Event logs)
Clearing the Event Log
Deleting Inputs
Deleting Keyfobs
Pulse Outputs:
I
keyfob: Pressing
,
or
on the keyfob will activate the relay for the
pulse time (3 or 60 seconds).
Input: The output will activate for the pulse time (3 or 60 seconds) after
an input has activated.
II
Pressing
will display the UR2 status
RED LED = ARMED, GREEN LED = DISARMED, ORANGE LED = FAULT
Toggle Outputs:
Keyfob:
Pressing only the
button on the keyfob will activate the relay.
Pressing only the
button will deactivate the relay.
I
Pressing
will display the error LED (blinks orange 4 times).
Input: The output will activate after an input has activated. The output
will only deactivate once the input has been activated a second time.
II
Pressing
will display the UR2 status (same as pulse mode).
Walk Test Mode:
M
The channel relay will open at the end of a successful walk test.
Technical Information Summary:
Supply Voltage:
9V – 15V
Current Consumption:
80mA (min) – 400mA(max, all outputs active)
3A @ 30VDC
Output A:
Output B:
3A @ 30VDC
Fault:
3A @ 30VDC
Arm / Disarm status:
0V (0V ARM), 9-15V (12V ARM)
Radio Frequency:
868MHz, FM Transceiver Narrow Band
Dimensions Plastic Box:
173x125x32mm
135x90x15mm
Dimensions PCB:
Operational Temperature:
-10°C to +50°C
Storage Temperature:
-40°C to +80°C
Humidity:
85% @ 25°
Product Information
For electrical products sold within the European Community. At the end of the
electrical products life, it should not be disposed of with household waste. Please
recycle where facilities exist. Check with your Local Authority or retailer for recycling
advice in your country.
To prevent possible damage to components, any static charge on your body needs to
be eliminated before touching the inside of the unit. This can be accomplished by
touching some grounded/earthed metallic conductor such as a radiator/pipework
immediately before handling the product.
Warranty
This product is sold subject to our standard warranty
conditions and is warranted against defects in
workmanship for a period of two years. In the interest
of continuing care and design, Pyronix Ltd reserves the
right to amend specifications, without giving prior
notice.Please see the control panels programming
manuals for further information.
 0845 6434 999 (UK). +44(0)1709 535 225
START
12V
0V
12V
ARM
0V
ARM
12V
0V
(FAST)
(VELOCE)
0
Example Disarm Status
after Alarm (Output A)
Signal Strength Indicator:
 customer.support@pyronix.com
 www.pyronix.com
OUTPUT A & B Wiring:
POWER SUPPLY
N/O (Normally Open)
+12VDC
Supply
OUTPUT
(A/B)
FAULT OUTPUT Wiring:
N/O (Normally Open)
FAULT
Learning Inputs:
ARM / DISARM:
Control
Panel
UR2-WE
(SLOW)
(LENTO)
1
DISPLAYS EVENTS IN ORDER ONCE DISARMED
MOSTRA GLI EVENTI ORDINE UNA VOLTA DISARMATO
≤300s
0-9
≤300s
≤300s
Pyronix Limited,Pyronix House,Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
= ALARM
= TAMPER
N/C (Normally Closed)
N/O DEOL
OUTPUT
OUTPUT
(A/B)
(A/B)
= ALARM
= TAMPER
N/C (Normally Closed)
N/O DEOL
FAULT
FAULT
0-9
>5s
Learning Keyfobs:
>5s
A-F
15s
N/C DEOL
OUTPUT
(A/B)
N/C DEOL
FAULT
RINS1702-3

Advertisement

loading

Summary of Contents for HIKVISION Pyronix UR2-WE

  • Page 1 UR2-WE START OUTPUT A & B Wiring: POWER SUPPLY = ALARM = TAMPER Dual channel universal receiver N/O (Normally Open) N/C (Normally Closed) N/O DEOL N/C DEOL for Enforcer inputs and keyfobs +12VDC Supply E N G L I S H Environmental Class II References: Output A and Output B:...
  • Page 2 Tasto Storico Eventi Event History Key Clearing the Event Log Event Log (History): Examples <2s Devices: Dispositivi: UR2-WE = Universal Receiver Ricevitore Universale TAMPER = Inputs 0-9, Output A Ingressi 0-9, Uscita A Beep <2s INPUT 1 = Inputs 0-9, Output B Ingressi 0-9, Uscita B >3s ALARM...
  • Page 3 UR2-WE Doppelkanal- UR2-WE Dubbelkanaals universele UR2-WE UR2-WE UR2-WE Ricevitore universale a Récepteur double canal Récepteur double canal Universalempfänger für ontvanger voor doppio canale per universel pour entrées universel pour entrées Enforcer-Eingänge und - Enforcer-inputs en telecomandi d'Enforcer et porte-clés d'Enforcer et porte-clés Schlüsselanhänger handzenders e ingressi Enforcer...
  • Page 4 UR2-WE UR2-WE Recetor universal de UR2-WE UR2-WE Dwukanałowy odbiornik Receptor Universal de dos canal duplo para uniwersalny do Canales para Entradas del comandos e entradas programowania wejść Ejecutor y Transmisores de Enforcer Enforcer i pilotów E S P A Ñ O L P O R T U G U Ê...