Download Print this page

Honeywell OMV-VX Series Installation Instructions Manual

Outdoor visual verification detector

Advertisement

Quick Links

OMV-VX Series Outdoor Visual Verification Detector - Installation Instructions
General
The OMV-VX series, visual verification outdoor detectors, are
wireless, battery operated, motion activated outdoor camera
designed for use with the Videofied security system.
Models
OMV-VX200 : 868 MHz (Europe, Africa, Asia)
OMV-VX601 : 915 MHz (USA, Canada, South America)
OMV-VX702 : 920 MHz (Australia, South America)
Features
Powered by 3 Lithium batteries for extended battery life.
4 infrared LEDs for night vision.
Transmits check-in/status signal every 8 minutes.
12 m (40 ft.) by 90 degree flexible detection pattern
adjustable to 5 ranges
SMDA Logic for advanced temperature compensation and
environmental noise immunity.
• Easy Masking for over spill prevention
• Double Conductive Shielding against bright light
disturbance
Battery box
Face cover
Cover unit
OMV-VX Series Parts Assembly
Use for masking optional area
Apply from the inside on a lens
Masking seal x 2
Options
( White )
( Silver )
( Black )
OMV-VX Accessories
Flange
Mounting plate
Back box
Main unit
OMV-003-V0
For wall mounting
Screw (4 × 20 mm)
Screw kit
Optional cover unit
Installation Notes
Symbol
Failure to follow the instructions provided with
Warning
this indication and improper handling may cause
death or serious injury.
Failure to follow the instructions provided with
Caution
this indication and improper handling may cause
injury and/or property damage.
Recommendation
Prohibition
Warning
Do not remove the PCB.
Caution
0.8 – 1.2 m
(2.64 – 3.94 ft)
Parallel
Meaning
Keep product away from
direct splash.
Tilt
OMV-001-V0

Advertisement

loading

Summary of Contents for Honeywell OMV-VX Series

  • Page 1 OMV-VX Series Outdoor Visual Verification Detector - Installation Instructions General Installation Notes The OMV-VX series, visual verification outdoor detectors, are Symbol Meaning wireless, battery operated, motion activated outdoor camera designed for use with the Videofied security system. Failure to follow the instructions provided with...
  • Page 2: Battery Installation/Replacement

    1 Disassembly 2 Battery Installation/Replacement SAFT LS14500 Remove face cover and flange Panasonic or Duracell CR123 Unlock cover unit - Reverse polarity - Mix up old and new - Excessive turn OMV-012-V0 - Reverse rotation 3 Installation Snap! Lock Unlock METAL BAND * Use a metal band with 25mm or less in width...
  • Page 3 4 Horizontal Area Adjustment (Continued) 5 Area Masking Disassemble the cover unit. A B C E F G Horizontal position D (Default) A B C E F G A B C E F G Attach the masking seal. Unwanted object (Tree) A B C E F G A B C...
  • Page 4: Device Test

    7 Enrolling the Sensor Refer to the control panel’s programming instructions. Put control panel into PROGRAMING/ PROGRAMMING/CONFIGURATION mode. CONFIGURATION Using a programmed alphanumeric keypad, step through menu options until “ADD A NEW DEVICE” is displayed. ADD A NEW Select OK or YES. “PRESS PROGRAM BUTTON OF DEVICE ? DEVICE”...
  • Page 5 7 Vertical Area Adjustment (3.3) (17) (33) (40) IMPORTANT BOTH DETECTION AREAS MUST BE BLOCKED FOR DETECTION Both upper and lower detection area are triggered Detection! Only upper detection area is triggered Detection Only lower detection area is triggered Detection OMV-023-V0 Resetting the Sensor Memory The OMV-VX memory must be cleared in order to pair the...
  • Page 6: Specifications

    Specifications* Model OMV-VX200 OMV-VX601 OMV-VX702 Panel compatibility Videofied W, XL, XT, XV and their variants Detection Detection method Passive Infrared PIR Coverage 12.0 m (40 ft) 90° wide / 16 zones PIR distance limit 12 – 2.5 m (5 levels) Detectable speed 0.3 –...
  • Page 7 (3.3) (17) (33) (40) For the latest documentation and online support, please Length limiting position 2 go to: https://mywebtech.honeywell.com/ https://support.videofied.com Length limiting position 3 For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa. For patent information, see www.honeywell.com/patents Length limiting position 4...
  • Page 8 2 Corporate Center Drive, Suite 100 P.O. Box 9040 Melville, New York 11747 Copyright © 2016 Honeywell International Inc. security.honeywell.com/OMV-VX Ê800 Ê800 Ê800 Ê800- - - - 22848kŠ 22848kŠ 22848kŠ 22848kŠ 800-22848 12/16 Rev A...

This manual is also suitable for:

Omv-vx200Omv-vx601Omv-vx702