OPERATION

TESTING THE LIGHT FIXTURE
CAUTION: Make sure the motion sensor head is not UPSIDE DOWN.
• Turn on the circuit breaker and light switch.
NOTE: When first turned on wait about 1 minute for the circuitry to calibrate.
• Slide the AUTO/TEST switch to TEST position on back of the motion sensor head (D).
• Loosen the wing screw to adjust the motion sensor head (D) toward desired detection area.
• Walk through the coverage area at the farthest distance you wish your detector to detect motion (max 72 ft).
• To adjust the fixture' s sensitivity to motion, rotate the SENS knob clockwise to increase sensitivity and counterclockwise to reduce the sensitivity.
• To set the amount of ON time you want the lights to stay on after the motion is detected, rotate the TIME knob to point to the desired time setting within the
TIME range (up to 18 minutes).
• After the setting is completed, slide the AUTO/TEST switch to AUTO position to resume normal function.
• In test mode, after sensor is triggered, light would go off automatically in 5 seconds. The time knob function would not work in test mode.
NOTE: Avoid aiming the control at:
• Objects that change temperature rapidly to prevent false triggering, such as heating vents and air conditioners.
• Moving objects such as trees and street traffic.

MANUAL MODE

1. When placing the ON/OFF switch in the ON position, lights will turn on at night with a maximum light output of 400 lumen and when motion is detected,
lights will have a maximum light output of 2400 lumen.
2. When placing the ON/OFF switch in the OFF position, lights will not turn on until motion is detected at night with a maximum light output of 2000 lumen.