Appendix 4 Emc And Low Voltage Directives; Measures To Comply With The Emc Directive - Mitsubishi Electric NZ2GF2B1-16D User Manual

Cc-link ie field network remote i/o module
Table of Contents

Advertisement

Appendix 4
Compliance to the EMC Directive, which is one of the EU Directives, has been a legal obligation for the products sold
in European countries since 1996 as well as the Low Voltage Directive since 1997.
Manufacturers who recognize their products are compliant to the EMC and Low Voltage Directives are required to
attach a "CE mark" on their products.
(1) Sales representative in EU member states
Authorized representative in EU member states is shown below.
Name: Mitsubishi Electric Europe BV
Address: Gothaer Strasse 8, 40880 Ratingen, Germany
Appendix 4.1
The EMC Directive specifies that "products placed on the market must be so constructed that they do not cause
excessive electromagnetic interference (emissions) and are not unduly affected by electromagnetic interference
(immunity)".
This section summarizes the precautions on compliance with the EMC Directive of the machinery constructed with the
module.
These precautions are based on the requirements and the standards of the regulation, however, it does not guarantee
that the entire machinery constructed according to the descriptions will comply with abovementioned directives.
The method and judgment for complying with the EMC Directive must be determined by the person who constructs the
entire machinery.
(1) EMC Directive related standards
(a) Emission requirements
Specifications
CISPR16-2-3
Radiated emission
EN61131-2: 2007
CISPR16-2-1,
CISPR16-1-2
Conducted emission
*1
QP: Quasi-peak value, Mean: Average value
*2
The module is an open type device (a device designed to be housed in other equipment) and must be installed inside a
conductive control panel. The tests were conducted with the module installed in a control panel.
286
EMC and Low Voltage Directives

Measures to comply with the EMC Directive

Test item
Test details
Radio waves from the product are
*2
measured.
Noise from the product to the power
line is measured.
*2
Standard value
• 30M-230MHz QP: 40dBV/m (10m in measurement range)
• 230M-1000MHz QP: 47dBV/m (10m in measurement range)
• 150k-500kHz QP: 79dB, Mean: 66dB
• 500k-30MHz QP: 73dB, Mean: 60dB
*1
*1

Advertisement

Table of Contents
loading