2-1. Air Discharge Chamber for Top Discharge

Install the air-discharge chamber in the field when:
it is difficult to keep a space of minimum 2 ft.
between the air-discharge outlet and the obstacle.
the air-discharge outlet is facing the sidewalk and
discharged hot air can annoy the passers-by.
Refer to Fig. 2-4.

2-2. Wind Shield for "CL" Model

Important
It is recommended to use wind shields for "CL" model
(Fig. 2-5). "CL" model is designed to use in low out-
door temperature conditions.
General
When the outdoor unit is installed in a position ex-
posed to strong wind (like seasonal winds with low air
temperature in winter), wind shield must be installed
on the outdoor unit.
This unit is designed so that the fan of the outdoor unit
runs at low speed when the air conditioner is operated
at low outdoor air temperatures. When the outdoor unit
is exposed to strong wind, the system pressure drops
because of the freeze protector.
For outer dimensions of wind shield, please see
Fig. 2-6.
22-5/16"
23-5/16"
CL3032, 3632
Wind shield
(air discharge side)
Recommended outer dimensions of wind shield
(field supply)
11-13/16"
1-7/32"
9-27/32"
5-5/32"
1352_C_I
9
S4359249
Air discharge
0426_C_I
Fig. 2-4
Front
0935_C_I
Fig. 2-5
21-13/16"
9-27/32"
21-13/16"
CL2432
Fig. 2-6
5-5/32"
0936_C_I