MEASUREMENT

Measure each value according to the following table and figure, if necessary.
Measurement point
VDD1
Min.
Max.
VDD2
Min.
Max.
VP
Min.
Max.
Ibat
Typ.
(Displaying)
Max.
Ibat
Typ.
(Printing)
Max
Ibu
Min.
(Power off)
Max.
Note : Ibat = Power source (Batteries or AC adaptor)
Ibu = Back-up battery (CR2032)
Vbat = 12V ± 2%)
Vbat
V
GND
Voltage / Current
4.72V
IDD1 = 30 mA
5.4V
4.72v
IDD2 = 30 mA
5.4v
11.70V
IP = 300 mA
12.24V
25 mA
Turning power SW on.
100 mA
When printing "CASIO COM..." at diagnostic program
0.6A
PRINT CHECK-1.
0.7A
When printing " ! " at diagnostic program PRINT CHECK-1.
----
Turning power SW off and disconnecting power
15 µA
source Vbat. Then supply +3V from CR2032.
Table-1
PCB L271-1
Ibat
DP1
A
Ibu
A
DP7
CR2032
DP2
Figure-7
— 5 —
Condition
IDD1
A
VDD1
(DP8)
V
IDD2
VDD2
A
DP6
V
VP
A
DP5
V
IP