Frequent Cycling
The Venturi control is designed for use on appliances that
typically cycle three to four times an hour during only the
heating season. In year-around applications with greater
cycling rates, the control can wear out more quickly.
Perform a monthly checkout.
Water or Steam Cleaning
If a control gets wet, replace it. If the appliance is likely to
be cleaned with water or steam, protect (cover) the
control and wiring from water or steam flow. Mount the
control high enough above the bottom of the cabinet so it
does not get wet during normal cleaning procedures.
High Humidity or Dripping Water
Dripping water can cause the control to fail. Never install
an appliance where water can drip on the control. In
addition, high ambient humidity can cause the control to
corrode and fail. If the appliance is in a humid
atmosphere, make sure air circulation around the control
is adequate to prevent condensation. Also, regularly
check out the system.
Ø1-15/16
(Ø49)

INSTALLATION

When Installing this Product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a
hazardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
69-2484EF—01
R 1-11/16 (42)
3-7/16
(97)
Fig. 1. Venturi Manifold dimensions in in. (mm).
Corrosive Chemicals
Corrosive chemicals can attack the control, eventually
causing failure. If chemicals are used for routine cleaning,
avoid contact with the control. Where chemicals are
suspended in air, as in some industrial or agricultural
applications, protect the control with an enclosure.
Dust or Grease Accumulation
Heavy accumulations of dust or grease can cause the
control to malfunction. Where dust or grease can be a
problem, provide covers for the control to limit
contamination.
Heat
Excessively high temperatures can damage the control.
Make sure the maximum ambient temperature at the
control does not exceed the rating of the control. If the
appliance operates at very high temperatures, use
insulation, shielding, and air circulation as necessary to
protect the control. Proper insulation or shielding should
be provided by the appliance manufacturer. Verify that
proper air circulation is maintained when the appliance is
installed.
2X 22 30
THROTTLE
SCREW
GAS INLET
AIR INLET
1-9/16
(40)
1-11/16
(42)
OUTLET
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out control
operation as provided in these instructions.