Quick Links

FEATURES
-
Integral reset alarm push button
-
Accurate safety timer.
-
Individual timers for safety and
prepurge timing.
-
Supply voltage range 220 ... 240 V.
EN1R--9102 9402R1--NE
AUTOMATIC IGNITION CONTROLLER
-
Full operating sequence after flame
loss.
-
Optional internal medium power
50 Hz spark igniter with 20 cm cable
and 2,8 x 0,8 mm spade terminal for
extended wiring.
-
Connection for external high power
igniter (S720)
R4560
INSTRUCTION SHEET
Description
The R4560 is a solid state automatic
direct burner ignition as well as
intermittent ignition controller with
excellent performance and high
reliability standard.
Application
The R4560 provides automatic
sequence control for:
-
Power burners up to 350 kW in
accordance with DIN 4788 part 2
and 3 including flame supervision
and non volatile lockout for
intermittent operation.
-
Power burners in accordance with
European safety standards EN 298.
-
Warm air heaters in accordance with
DIN 4794 part 3 (-- 20 EC).
-
Lockout in case of air proving switch
detects no air.
-
Lockout in case of flame simulation
before start or during prepurge.
-
Sequence status diagnostic
indicators by 4 LED's.

Advertisement

loading

Summary of Contents for Honeywell R4560

  • Page 1 R4560 AUTOMATIC IGNITION CONTROLLER INSTRUCTION SHEET Description The R4560 is a solid state automatic direct burner ignition as well as intermittent ignition controller with excellent performance and high reliability standard. Application The R4560 provides automatic sequence control for: Power burners up to 350 kW in...
  • Page 2 WIRING DIAGRAMS Fig. 2 Direct burner ignition Fig. 1 Intermittent pilot ignition OPERATION SEQUENCES 5 s max. 5 s max. Fig. 4 Direct burner ignition Fig. 3 Intermittent pilot ignition Thermostat Gas valve Ignition Flame rod Limiter Reset switch Alarm Air proving Gas pressure switch...
  • Page 3 SPECIFICATIONS Model Electrical rating An external (more powerful) ignition 1 A cos ϕ =0.6 R4560: 220 ... 240 V, 50 Hz. Valve output: transformer (S720) can be wired in 1 A cos ϕ =0.6 Suffix M: For power burners. Fan: the system.
  • Page 4 High temperatures will affect product controller must be repaired by shielded environment. life negatively. Honeywell. Note When the automatic ignition controller For safety a high limit thermostat must Electrical rating of connected controls is built in an appliance, the total...