Code
0609h
FIFO trigger level test failed at port
XXXXh.
0610h
FIFO character timeout indication test
failed at port XXXXh.
0611h
FIFO data transfer test failed at port
XXXXh.
0701h – 0705h: Parallel Port Error Codes
Code
0701h
Data written to port XXXXh was yyh.
Data read back was zzh.
0702h
IRQ Activation test failed at port XXXXh.
0704h
ECP register W/R test failed at port
XXXXh.
0705h
ECP FIFO test failed at port XXXXh.
0706h
Loopback test failed at XXXXh port.
0707h
Loopback test failed at XXXXh port.
Explanation
Explanation
0701h – 0705h: Parallel Port Error Codes
Details/Parts to Check
Serial port controller error.
Install new system board.
Serial port controller error.
Install new system board.
Serial port controller error.
Install new system board.
Details/Parts to Check
Parallel port or parallel port controller error.
Check that external loopback (test) connector is
correctly installed.
If error persists install new system board.
Parallel port controller error.
Install new system board.
Parallel port controller error.
Install new system board.
Parallel port controller error.
Install new system board.
Install new parallel port controller.
Loopback connector missing.
Connect loopback connector.