Remember, the antenna should be as inconspicuous as possible for greatest visual security.
Try to keep the antenna away from sources of RF interference, including pumps, compressors, ovens,
etc., or where metal objects can shield it or otherwise block the cellular radio RF signal.
Place the antenna perpendicular to the ground, pointing either straight up or down. Do not mount the
antenna horizontally. Mount the Telguard unit to the wall or other surface near the alarm panel. Care should
be taken to avoid equipment that may make receiving a clear cellular signal difficult.
Attach earth ground to the grounding screw located on lower right-hand corner of printed circuit board
assembly and permanently mount the Telguard enclosure.
Install mounting screws.
Slide the enclosure onto these screws.
Verify unit is secured by tightening screws and/or by placing additional screws in lower mounting holes.
Install Optional TG-PEM Accessory into TG-7 or TG-7FS (if using)
The TG-PEM Power and Expansion Module can be used to convert 24VDC fire panel power to the necessary
voltage to operate the TG-7FS. It can also be used to add 8 24-hour dry contact zones (16 with two TG-PEM
units) to a TG-7.
The TG-PEM should be installed after the TG-7 series device has been mounted to the wall or other surface.
Follow the instructions for the TG-PEM to install it. After installation of the TG-PEM, proceed to Option 2 in
the next section.
Note: When the TG-PEM is used to provide power, the TG-7 series device cannot have an AC power
transformer or backup battery connected.
Complete all Power-Related Wiring Connections
Option 1: Backup Battery and AC Power Transformer
To apply power to the Telguard, attach a battery to the battery connector jack using the supplied battery
cable. If the need for a different size cable arises, the Telguard provides an alternate screw-in terminal
connection for the battery. Backup battery must be sized appropriately to meet installation requirements.
Connect the Telguard AC power transformer (see A6 for acceptable UL Listed transformers) to AC terminals
using stranded copper insulated wire following wire gauge and length recommendations below:
Option 2: DC Power
When using this option, no other power connections (battery or AC) should be wired.
Power to the TG-7 series device may be sourced from the host alarm panel 12VDC auxiliary output. Connect
the power and ground connections into the respective DC and GND connections on the TG-7 Series using
the 2-position terminal block provided.
Note: If alarm panel output voltage is higher (e.g., 24VDC), the TG-PEM accessory is required.
LS10265-000HW-E:D 06/03/2021
Recommended Wire Size Length Not to Exceed
18 ga
16 ga
14 ga
20 ft
40 ft
60 ft
12
56052901 – Rev B