In the case of a cartridge filter blocked with a bracket and threaded knob, (fig. C), unscrew
the knob, remove the locking bracket and then remove the active carbon filter. Replace the
carbon filters and the metal non-grease filters by performing the operations in inverse order
Note: only the electronically-controlled hood can the filter cleaning warning function
be reset by pressing the specific filter reset button
REPLACEMENT LAMPS:
EN
Before performing any maintenance
and/or cleaning always disconnect
the hood from the power supply
Depending on the model, the hood can be
equipped with different types of lighting, with LED
or halogen lamps:
a) WITH LED LIGHTS: The LED lights guarantee
a significant number of hours of operation.
Should it be replace due to being worn or faulty,
the entire spotlight must be replaced. In this
case, contact qualified Technical Support. This
appliance is equipped with Class 1M white LED
light, in accordance with EN standard 60825-1:
1994 + A1:2002 + A2:2001; maximum emitted
optical power@439nm: 7μW.
Do not look directly at the light with optical
instruments (binoculars, magnifying glass...).
b) Halogen: lamp with G4 fitting, 20W power and
12V voltage. Replace the lamp by removing
the glass support ring of the spotlight with
a screwdriver. Once the glass is removed,
remove the faulty lamp from its housing and fit
the new lamp. Replace the glass of the spotlight
by blocking it with the ring.
Code ILCOS: HSG/C/UB-20-12-G4