Appendix; Troubleshooting; General - Yamaha YSP-5600BMK2 Owner's Manual

Digital sound projector
Table of Contents

Advertisement

APPENDIX

Troubleshooting

Refer to the chart below when this unit does not function properly. If the problem you are experiencing is not listed below or if the instruction below does not help, turn off the unit,
disconnect the AC power supply cable, and contact the nearest authorized Yamaha dealer or service center.

General

Problem
This unit does not operate
The internal microcomputer has been frozen by an external electric shock
properly.
(such as lightning or excessive static electricity) or by a power supply with
low voltage.
This unit fails to turn on when the
The AC power supply cable is not firmly connected to the AC wall outlet.
z key is pressed, or the unit is
The internal microcomputer has been frozen by an external electric shock
turned off soon after the power
(such as lightning or excessive static electricity) or by a power supply with
has been turned on.
low voltage.
"PANEL LOCK" is set to "ON".
This unit is suddenly turned off.
The internal temperature becomes too high and the overheat protection
circuitry has been activated.
When the Auto Power Standby function is enabled, this unit turns off
automatically in any of the following situations:
– Audio is coming from the selected input source, but no operations have
been performed for 8 hours or more.
– HDMI1–4, Bluetooth or NET is selected as the input source, but no audio
has been input to the unit or no operations have been performed with the
unit for more than 20 minutes.
The network standby function has been activated, terminating the Bluetooth
connection.
Cause
Disconnect the AC power supply cable from the outlet and plug it again in
after 30 seconds.
Connect the AC power supply cable firmly to the AC wall outlet.
Disconnect the AC power supply cable from the outlet and plug it again in
after 30 seconds.
Set to "OFF".
Wait for about 1 hour for this unit to cool down, turn it back on after
confirming an adequate amount of ventilation space and not to cover this
unit with a cloth.
Turn on the power of the unit and play back the source again. If the Auto
Power Standby function is not used, set "AUTO POWER STANDBY" to
"OFF".
Resume the Bluetooth connection using the Bluetooth device, or turn on
this unit and disable the network standby function.
Remedy
APPENDIX ➤ Troubleshooting
See page
26
85
12
86
81
90
En

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ysp-5600

Table of Contents