Installing The Compressor Casing; Fig. 45: Fitting The Wall Insert And The Diffuser; Table 39: Tightening Torque (79041) - ABB HT581373 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A130-H.. - A140-H
8 Dismantling and fitting / 8.15 Installing the compressor casing
8.15

Installing the compressor casing

Fitting the wall insert and the diffuser
Fig. 45: Fitting the wall insert and the diffuser
Part number
79041
Table 39: Tightening torque (79041)
1. Always replace the O-ring (77005) (see section Spare parts).
2. Install the wall insert (77000) in the compressor casing.
3. Secure the diffuser (79000) with fixing discs (79040) and screws (79041).
© Copyright 2018 ABB. All rights reserved.
A130
M6
8 Nm
HZTL4030_EN
A135
M6
8 Nm
Revision E
A140
M6
8 Nm
September 2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

A140-h55

Table of Contents