Installing the compressor casing

Fitting the wall insert and the diffuser
Fig. 45: Fitting the wall insert and the diffuser
Part number
A130
A135
A140
79041
M6
M6
M6
8 Nm
8 Nm
8 Nm
Table 38: Tightening torque (79041)
1. Always replace the O-ring (77005) (see section Spare parts).
2. Install the wall insert (77000) in the compressor casing.
3. Secure the diffuser (79000) with fixing discs (79040) and screws (79041).