Communication operation and setting
Real-time monitor
Refer to page 143 for details of the monitor description.
Register
Description
40201
Output frequency/Speed
40202
Output current
*8
40203
Output voltage
*8
40205
Frequency setting value/Speed setting
40206
Running speed
40208
Converter output voltage
40209
Regenerative brake duty
Electronic thermal relay function
40210
load factor
40211
Output current peak value
40212
Converter output voltage peak value
40213
Input power
40214
Output power
40215
Input terminal status
40216
Output terminal status
40217
Load meter
40220
Cumulative energization time
40223
Actual operation time
40224
Motor load factor
40225
Cumulative power
40250
Power saving effect
....
Specifications differ according to the date assembled. Refer to page 399 to check the SERIAL number.
*1
The setting depends on capacities. (FR-F720-02330 (FR-F740-01160) or lower/FR-F720-03160 (FR-F740-01800) or higher)
Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, ⎯: undetermined value)
*2
b15
Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, ⎯: undetermined value)
*3
b15
*4
When Pr.37 = "1 to 9998" or Pr. 144 = "2 to 10, 102 to 110," the unit is an integral value (one increment). (Refer to page 141)
*5
Option input terminal 1 monitor details (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0) -all terminals
are OFF when an option is not fitted
b15
X15
X14
X13
*6
Option input terminal 2 monitor details (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0,
⎯: undetermined value) -all terminals are OFF when an option is not fitted
b15
*7
Option output terminal monitor details (output terminal status of FR-A7AY/A7AR when the terminal is ON: 1, when the terminal is OFF: 0,
⎯: undetermined value) -all terminals are OFF when an option is not fitted
b15
*8
The monitored values are retained even if an inverter fault occurs. Resetting will clear the retained values.
244
Increments
0.01Hz/1
*4 *8
0.01A/0.1A
0.1V
0.01Hz/1
*4
1r/min
0.1V
0.1%
0.1%
0.01A/0.1A
0.1V
0.01kW/0.1kW
0.01kW/0.1kW
*2
*3
0.1%
1h
1h
0.1%
1kWh
Variable
CS
RES
STOP
X12
X11
X10
X9
RA3
Register
40251
Cumulative saving power
40252
PID set point
*1
40253
PID measured value
40254
PID deviation
Option input terminal status 1
40258
*5
Option input terminal status 2
40259
*6
Option output terminal status
40260
*1
*7
40264
PTC thermistor resistance
*1
40267
PID measured value 2
*1
32-bit cumulative power
40277
(lower 16-bit)
32-bit cumulative power
40278
(upper 16-bit)
32-bit cumulative power
40279
(lower 16-bit)
32-bit cumulative power
40280
(upper 16-bit)
MRS
JOG
RH
RM
ABC2
ABC1
X8
X7
X6
X5
RA2
RA1
Y6
Y5
Description
RL
RT
AU
FU
OL
IPF
X4
X3
X2
Y4
Y3
Y2
Increments
Variable
0.1%
0.1%
0.1%
0.01kΩ
0.1%
1kWh
1kWh
0.01kWh/
0.1kWh
*1
0.01kWh/
0.1kWh
*1
b0
STR
STF
b0
SU
RUN
b0
X1
X0
b0
DY
b0
Y1
Y0