4.11.5 How to calibrate the terminal CA when using the operation panel (FR-DU07)

Operation
1.
Confirmation of the operation status indicator
and operation mode indicator
2.
Press
to choose the parameter
setting mode.
3.
Turn
until
4.
Press
to display
5.
Turn
until
Set to C0 CA terminal calibration.
6.
Press
to enable setting.
7.
If the inverter is at a stop, (press
or
) to start the inverter.
(Motor needs not be connected.)
8.
Turn
to adjust the indicator needle
to the desired position.
9.
Press
. Setting is complete.
REMARKS
⋅ Calibration can also be made for external operation. Set the frequency in External operation mode, and make calibration in the
above procedure.
⋅ Calibration is available even during operation.
⋅ For the operating procedure using the parameter unit (FR-PU04/FR-PU07), refer to the parameter unit instruction manual.
♦ Parameters referred to ♦
C0 CA terminal calibration
C1 AM terminal calibration
appears.
.
appears.
(
)
+
-
Flicker...Parameter setting complete!!
Turn
to read another parameter.
Press
to return to the
Press
twice to show the next parameter (
Refer to page 151
Refer to page 151
Monitor display and monitor output signal
Display
(When Pr. 54 = 1)
The parameter
number read
previously appears.
C0 to C11
setting
is enabled.
The monitor set to Pr. 54 CA terminal
function selection is displayed.
Analog indicator
indication (step 4).
).
4
153