E&M Tie Line Timer - NEC SL2100 Programming Manual

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

SL2100
Level:
IN
Description
Use Program 34-07 : E&M Tie Line Timer to define the system service tone timers.
Program
34
Input Data
Item
No.
01
First Digit Pause (E&M Immediate
Start)
02
First Digit Pause (E&M Wink Start)
03
First Digit Pause (LD Trunk)
04
LD Trunk Guard Time
05
Trunk Answer Detect Timer for
E&M
Conditions
• If Program 34-07-05 is left at default (30) the transferred call recalls to the station that performed the
transfer when not answered.
Feature Cross Reference
None
2-374
Program 34 : Tie Line Setup
Item
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
34-07 : E&M Tie Line Timer
Input Data
Program 34 : Tie Line Setup
ISSUE 2.0
Default
3 seconds
0
3 seconds
0
30 seconds

Hide quick links: