9-16 Upgrading Your Server
IMPORTANT:
too much pressure can damage the socket. Keyed DIMMs insert only
one way.
NOTE:
side of the DIMM has a cut-out to prevent an incorrect insertion.
If the DIMM is inserted into the DIMM socket, the lever is automatically closed.
10.
Close the lever firmly.
11.
Install the DIMMs in another DIMM connector according to steps 8 through 10.
12.
Install the components removed in steps 1 and 2.
13.
Make sure that no error message appears on the POST screen.
See Chapter 8 for details of the POST error messages.
14.
Run SETUP and select menus in the order of [Advanced] and [Memory Configuration] to
make sure that "DIMM Group #1 Status" is set to "Normal" (see Chapter 4).
15.
Set [Advanced] – [Reset Configuration Data] in the [Advanced] menu to [Yes].
This is required to update the hardware configuration information. See Chapter 4 for
details.
16.
Set the paging file size to a value larger than the recommended value (installed memory *
1.5) (for Windows).
Use extreme care when installing a DIMM. Applying
Make sure of the orientation of the DIMM. The connecting