NEC Express5800 User Manual page 141

Hide thumbs Also See for Express5800:
Table of Contents

Advertisement

On-screen error message
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error
0B99
BMC Fatal hardware error.
0B9A Management controller not responding
0B9B Private I2C bus not responding.
0B9C BMC internal exception
0B9D BMC A/D timeout error.
0B9E SDR repository corrupt.
0B9F SEL corrupt.
0BB0 SMBIOS - SROM data read error.
0BB1 SMBIOS - SROM data checksum bad.
0BD0 1st SMBus device address not acknowledged.
0BD1 1st SMBus device Error detected.
0BD2 1st SMBus timeout.
0BD3 2nd SMBus device address not acknowledged.
0BD4 2nd SMBus device Error detected.
0BD5 2nd SMBus timeout.
0BD3 3rd SMBus device address not acknowledged.
0BD4 3rd SMBus device Error detected.
0BD5 3rd SMBus timeout.
0BD9 4th SMBus device address not acknowledged.
0BDA 4th SMBus device Error detected.
0BDB 4th SMBus timeout.
0BDC 5th SMBus device address not acknowledged.
0BDD 5th SMBus device Error detected.
0BDE 5th SMBus timeout.
0BE8 IPMB device address not acknowledged.
0BE9 IPMB device Error detected.
0BEA IPMB timeout.
8100
Memory decreased in Size
Expansion Rom not initialize
Invalid System Configuration Data
Resource Conflict
System Configuration Data Read error
System Configuration Data Write error
WARNING: IRQ not configured
IMPORTANT:
displayed due to insufficient expansion ROM area. Select one of the
features of the lowest frequency and set it to "Disabled".
– On board LAN 1/On board LAN 2
– PCI slot 1
The message "Expansion Rom not initialized" may be
Troubleshooting 8-5
Action
Power off and reboot the CPU blade. If
the error persists, contact your service
representative.
Contact your service representative.
Run the BIOS SETUP utility to disable
the use of expansion ROM area and
PCI slot OptionROM. If the error
persists, contact your service
representative.
Contact your service representative.

Advertisement

Table of Contents
loading

Table of Contents