14/43
Bosch Rexroth AG | Electric Drives
Technical Data
4.3

Ambient Conditions

4.4

Standards

4.4.1

Used Standards

Rexroth IndraControl VAU01.1S | Project Planning Manual
and Controls
In operation
Surrounding air
+5 to +45 °C
temperature
Max. tempera‐
Temporal temperature changes
ture gradient
up to 3 °C per minute
Relative humid‐
Climatic class 3K3 according to
ity
EN 60721, non-condensing.
Max. 80% humidity for 25 °C
Air pressure
Up to 2000 m above NN accord‐
ing to DIN 60204
Mechanical
Max. vibration
strength
Frequency range: 10 to 150 Hz
Excursion: 0.075 mm at 10 to 57
Hz
Acceleration: 1 g at 57 to 150 Hz
Test duration for each axis: 10
frequency cycles
Frequency sweep rate:
1 octave/min
according to EN 60068-2-6, Test
Fc
Degree of pollu‐
2
tion
Fig.4-4:
Ambient conditions
TheVAU01.1S system components comply with the following standars:
Standard
EN 61 000-6-4
EN 61 000-6-2
EN 61 558-2-6
EN 60 664-1
EN 61 131-2
EN 60 529
EN 60 068-2-6
Storage/transport
-20 °C to +60 °C
Temporal temperature changes
up to 3 °C per minute
Climatic class 3K3 according to
EN 60721, non-condensing.
Max. 80 % humidity for 25 °C
Up to 3000 m above NN accord‐
ing to DIN 60204
Max. shock:
15 g according to EN 60
068-2-27, no disturbance of the
function
2
Meaning
Generic emission standard (industrial environment)
Generic standard, noise immunity (industrial environ‐
ment)
Transformer for 24-V power supply unit, protective sep‐
aration
Overvoltage category II
24 V power supply requirements
Degrees of protection (including housing and installation
compartments)
Vibration test