APPLICATION
The VS820 and VS821 are used on gas fired, standing
pilot appliances with 750 mV self-powered control systems.
The gas controls include a manual gas valve, safety shutoff,
single millivoltage automatic operator and pressure regula-
tor. Refer to Table 1 for capacity ratings and Table 2 for
pressure regulators and temperature ratings. Separate
TABLE 1—VS820 AND VS821 PIPE SIZE AND CAPACITY RATINGS.
MODEL
PIPE SIZE
VS821
1/2 x 3/8
VS820
1/2 x 1/2
1/2 x 3/4
3/4 x 3/4
VS820
1 x 1
High Capacity
Capacity is based on 1000Btuh/ft
a
at 0.25 kPa pressure drop]. Use conversion factors in Table 3 to convert for other gases.
Reducer fittings must be obtained locally.
b
TABLE 2—PRESSURE REGULATOR AND TEMPERATURE RATINGS.
MODEL
PRESSURE
TYPE
VS820A,H
Standard
VS821A
VS820C, VS821C
Step
VS820D
Hi-Low
VS820P
Step
VS820V
Standard
TABLE 3—GAS CAPACITY CONVERSION FACTORS.
SPECIFIC
TYPE OF GAS GRAVITY
Manufactured
0.60
Mixed
0.70
Propane
1.53
INSTALLATION
WHEN INSTALLING THIS PRODUCT...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous
condition.
2. Check the ratings given in these instructions and on
the product to make sure the product is suitable for your
application.
3. Make sure installer is a trained, experienced service
technician.
4. After completing installation, use these instructions to
check product operation.
D.T.
Rev. 4-89
INLET x OUTLET
CAPACITY
cfh
m
3
110
3.1
225
6.4
250
7.1
335
9.5
600
17.0
, 0.64 sp gr natural gas at 1 in. wc pressure drop [37.3 MH/m
3
REGULATOR
MODEL
V5306A
V5307A
V5308A
V5307B
V5306A
MULTIPLY
LISTED CAPACITY BY
0.516
0.765
1.62
VS820A,C,D,H,P,V AND VS821A,C
MILLIVOLTAGE COMBINATION
GAS CONTROLS
models are available for natural and LP gas; the controls
cannot be field converted.
Power for the gas control and the control system is
provided by a 750 mV Powerpile generator. We recom-
mend the Q313 Thermopile Generator or the CS82, CS893,
CS894, or CS897 Pilot Burner Generators.
REDUCER FITTINGS
a
/hr
SIZE
—
—
3/4 x 1/2
1/2 x 3/8
3/4 x 1/2
3/4 x 1/2
1 x 3/4
1 x 3/4
TEMPERATURE RATING
°F
32 to 175
-40 to 175
WARNING
FIRE OR EXPLOSION HAZARD
CAN CAUSE PROPERTY DAMAGE, SEVERE IN-
JURY, OR DEATH
Follow these warnings exactly:
1. Disconnect power supply before wiring to pre-
vent electrical shock or equipment damage.
2. To avoid dangerous accumulation of fuel gas,
turn off gas supply at appliance service valve
before starting installation and perform Gas
Leak Test following installation.
3. Do not bend pilot tubing at control or at pilot
after compression fitting has been tightened.
Gas leakage at the connection fitting may
result.
4. Always install sediment trap in gas supply line
to prevent contamination of gas control.
5. Do not force gas control knob. Use only your
hand to turn gas control knob. If the knob will
not operate by hand, the control should be
replaced by a qualified service technician.
Force or attempted repair may result in fire or
explosion.
b
CAPACITY
cfh
m
3
/hr
—
—
—
—
225
6.4
110
3.1
250
7.1
225
6.4
503
14.2
450
12.7
, 0.64 sp gr natural gas
3
°C
0 to 79
-40 to 79
Form Number 95-6994—8
©Honeywell Inc. 1989