Ac Input Specifications; General Ac Input Specifications - ABB Terra 94 North America Operation And Installation Manual

Table of Contents

Advertisement

Technical data
Order
48
49
50
Total
10.16

AC input specifications

10.16.1

General AC input specifications

Parameter
Input AC power connection
Input voltage range
Power factor at full load
Efficiency
Total harmonic distortion (current)
A
B
94
Phase L1
IRMS
HDF
[A]
[%]
0.10
0.09
0.08
0.07
0.04
0.04
112.69
2816%
B
N
Input voltage between phase and
neutral
Input voltage between two phases
Phase L2
IRMS
HDF
[A]
[%]
0.12
0.11
0.11
0.10
0.06
0.05
112.36
2976%
Specification
3P + PE (WYE input)
480 VAC +/- 10% (60 Hz)
> 0.96
> 94% at nominal output power
< 5%
A
C
Upstream breaker in the power
distribution board
D
EVSE
Phase L3
IRMS
HDF
[A]
[%]
0.20
0.17
0.10
0.09
0.08
0.07
112.53
2804%
L1
L2
C
L3
PE
9AKK108466A3703-EN | 001

Hide quick links:

Advertisement

Table of Contents
loading