A/D PCB

1) Item to Be Adjusted:
Item
Clock adjustment
2) Adjustment and Test Point Locations:
3) Equipment Connection / Procedure
Input
Input
Connection Point
TOP VIEW
Clock Adjustment
Set
Output
TP6
Input
Output
Adjust
Signal
Connection
VR700
Voltmeter
— 6 —
Measuring Instrument
Voltmeter
VR700
Voltmeter
Output
Adjust for
Point
Adjust for 2.00 ± 0.05V
TP6
reading on voltmeter.